The Upside-Down Gore Excluder Limb and Double-Barrel Sandwich Technique for Penetrating Aortic Ulcer and Iliac Aneurysm Exclusion

نویسندگان

  • Hyung-Kee Kim
  • Incheol Song
  • Seung Huh
چکیده

Endovascular aneurysm repair has become the first-line treatment for abdominal aortic aneurysms and iliac artery aneurysms in recent years. However, the diameter of the infrarenal aorta is larger than that of the aortic bifurcation, especially with small aortic diameters, for which a reversed tapered device is necessary. We describe the off-label use of the upside-down Gore Excluder limb and double-barrel sandwich technique for the treatment of a penetrating abdominal aortic ulcer with a large common iliac artery aneurysm. These techniques offer an easy endovascular approach for excluding an aneurysm in selected patients. However, this technique is outside the standard instructions for use, therefore careful planning and long-term follow-up are mandatory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The new C3 Gore Excluder stent-graft: single-center experience with 100 patients.

OBJECTIVES To present results from the first 100 patients treated with the new C3 Gore Excluder stent-graft in a single institution. METHODS All patients treated with the C3 Excluder stent-graft between August 2010 and July 2013 in our institution were included. Patient demographics, treatment indication, need for intraoperative stent-graft repositioning, immediate technical success, survival...

متن کامل

Results of repair of iliac artery aneurysms with the sandwich technique.

Patients undergoing endovascular repair (EVAR) of aortoiliac or iliac artery aneurysm may require sacrifice of one or both internal iliac arteries (IIAs). Until Food and Drug Administration-approved commercial grafts became available, endovascular IIA preservation was accomplished using the "sandwich" technique, but limited information is available regarding the results of this method. After ob...

متن کامل

Endovascular repair of bilateral common iliac artery aneurysms using GORE Excluder iliac branch endoprosthesis without aortobi-iliac stent graft conjunction

INTRODUCTION Bilateral common iliac artery (CIA) aneurysm (CIAA) is a rare entity. In the past decade, different endovascular approaches have been adopted for patients with several comorbidities or unfit for open repair (OR). Recently, the use of iliac branch stent graft has been proposed, resulting in satisfactory patency rates and decrease in morbidity. Currently, according to instruction for...

متن کامل

Evolution of Endovascular Management of Common Iliac Artery Aneurysms

E ndovascular aneurysm repair (EVAR) has evolved to become the first choice in the treatment for patients with thoracic and abdominal aortic aneurysms (AAAs). Despite the success of endovascular techniques for abdominal and thoracic pathology, management of aortoiliac aneurysms (AIAs) remains challenging, with up to 30% of AAAs having concomitant common iliac artery aneurysms (IAAs). Typical st...

متن کامل

Successful off-label use of the GORE EXCLUDER Iliac Branch Endoprosthesis to preserve gluteal perfusion during staged endovascular repair of bilateral isolated hypogastric aneurysms

Endovascular repair of iliac artery aneurysms has emerged as an alternative to traditional open surgical repair. Although there is little consensus on indications to preserve hypogastric blood flow during aneurysm repair, it is well understood that complications from bilateral hypogastric occlusion may be significant. The GORE EXCLUDER Iliac Branch Endoprosthesis (W. L. Gore and Associates, Fla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2016