Performance of target-controlled sufentanil infusion in obese patients.
نویسندگان
چکیده
BACKGROUND Because obesity might affect pharmacokinetic parameters, the authors evaluated the accuracy of target-controlled sufentanil infusion in morbidly obese patients using a pharmacokinetic model usually applied to a normal-weight population. METHODS Target-controlled propofol and sufentanil coinfusions were administered to 11 morbidly obese patients (body mass index: 45.0 +/- 6.5 kg/m2 ) undergoing laparoscopic gastroplasty. The target plasma propofol concentration was 3 micro g/ml. The effect-site sufentanil target concentration was initially 0.4 ng/ml but was modified during surgery as a function of blood pressure and heart rate. Plasma sufentanil concentrations were measured from the onset of infusion until 24 h after its termination. The predicted sufentanil target concentrations were calculated by STANPUMP software. Intrasubject data analyzed included calculation of performance error, median performance error, median absolute performance error, divergence, and wobble. Pharmacokinetic analysis was performed using a nonlinear mixed effect model. RESULTS Applied sufentanil target concentrations ranged from 0.3 to 0.65 ng/ml. The mean +/- SD plasma sufentanil concentration measured during spontaneous ventilation was 0.13 +/- 0.03 ng/ml. Median performance error (range) was -13% (-42 to 36%). Median absolute performance error was 26% (8-44%) during infusion and 17% (12-59%) for the 24 h after its completion. The pharmacokinetic sets used slightly overpredicted the concentrations, with a median divergence of -3.4% (-10.2 to 3.1%) during infusion. For body mass index greater than 40, the overestimation of plasma sufentanil concentrations was greater. A two-compartment model with proportional error for interindividual variability best fitted the data. The residual variability was modeled as an additive (0.016 ng/ml) or proportional error (23%). Clearance, central volume of distribution, intercompartmental clearance, and peripheral volume of distribution (coefficient of variation) were 1.27 l/min (23%), 37.1 l (20%), 0.87 l/min (44%), and 92.7 l (22%), respectively. CONCLUSION The pharmacokinetic parameter set derived from a normal-weight population accurately predicted plasma sufentanil concentrations in morbidly obese patients.
منابع مشابه
Effects of sufentanil or ketamine administered in target-controlled infusion on the cerebral hemodynamics of severely brain-injured patients.
OBJECTIVE The manual injection of a bolus of opioid in patients with brain injury induces an increase in intracranial pressure related to a decrease in mean arterial pressure. Such an effect has not been observed with the use of ketamine. The use of target-controlled infusion would minimize or suppress this adverse effect of opioid. This study evaluated the effects of an increase in plasma conc...
متن کاملComparison of target-controlled infusion of sufentanil and remifentanil in blunting hemodynamic response to tracheal intubation
BACKGROUND Maintaining blood pressure (BP) and heart rate (HR) after laryngoscopy and tracheal intubation has always been a concern in injured patients. Opioids can attenuate or stop an increase in these two parameters if administered with proper doses or targets in target-controlled infusion (TCI). Remifentanil and sufentanil are widely used for this purpose because their cardiac side effects ...
متن کاملEffects of different doses of sufentanil and remifentanil combined with propofol in target-controlled infusion on stress reaction in elderly patients
The current study aimed to observe the effects of sufentanil and remifentanil combined with propofol in target-controlled infusion (TCI) on perioperative stress reaction in elderly patients. A total of 80 elderly patients requiring general anesthesia were recruited. They were divided into four groups (each n=20) according to different target concentrations of remifentanil and sufentanil. These ...
متن کاملMedian effective effect-site concentration of sufentanil for wake-up test in adolescents undergoing surgery: a randomized trial
BACKGROUND To determine the median effective concentration of sufentanil as an analgesic during wake-up tests after sevoflurane anesthesia during surgery for adolescent idiopathic scoliosis (AIS). METHODS This is a randomised controlled trial. Sixty patients aged 13-18 years scheduled for AIS surgery were randomized into six groups of 10 patients each to receive target effect-site concentrati...
متن کاملPreliminary results of prolonged target controlled infusion of sufentanil adjusted to an effort pain score after cardiac surgery.
Repeated boluses of i.v. morphine are often used for analgesia after cardiac surgery, but this procedure frequently provides inadequate pain relief. Target controlled infusion (TCI) of opioid drugs has been proposed as an alternative. The objective of this study was to evaluate the effects of prolonged sufentanil TCI adjusted to an effort pain score on the postoperative course after cardiac sur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 98 1 شماره
صفحات -
تاریخ انتشار 2003