High-resolution motion compensated MRA in patients with congenital heart disease using extracellular contrast agent at 3 Tesla
نویسندگان
چکیده
BACKGROUND Using first-pass MRA (FP-MRA) spatial resolution is limited by breath-hold duration. In addition, image quality may be hampered by respiratory and cardiac motion artefacts. In order to overcome these limitations an ECG- and navigator-gated high-resolution-MRA sequence (HR-MRA) with slow infusion of extracellular contrast agent was implemented at 3 Tesla for the assessment of congenital heart disease and compared to standard first-pass-MRA (FP-MRA). METHODS 34 patients (median age: 13 years) with congenital heart disease (CHD) were prospectively examined on a 3 Tesla system. The CMR-protocol comprised functional imaging, FP- and HR-MRA, and viability imaging. After the acquisition of the FP-MRA sequence using a single dose of extracellular contrast agent the motion compensated HR-MRA sequence with isotropic resolution was acquired while injecting the second single dose, utilizing the timeframe before viability imaging. Qualitative scores for image quality (two independent reviewers) as well as quantitative measurements of vessel sharpness and relative contrast were compared using the Wilcoxon signed-rank test. Quantitative measurements of vessel diameters were compared using the Bland-Altman test. RESULTS The mean image quality score revealed significantly better image quality of the HR-MRA sequence compared to the FP-MRA sequence in all vessels of interest (ascending aorta (AA), left pulmonary artery (LPA), left superior pulmonary vein (LSPV), coronary sinus (CS), and coronary ostia (CO); all p < 0.0001). In comparison to FP-MRA, HR-MRA revealed significantly better vessel sharpness for all considered vessels (AA, LSPV and LPA; all p < 0.0001). The relative contrast of the HR-MRA sequence was less compared to the FP-MRA sequence (AA: p <0.028, main pulmonary artery: p <0.004, LSPV: p <0.005). Both, the results of the intra- and interobserver measurements of the vessel diameters revealed closer correlation and closer 95 % limits of agreement for the HR-MRA. HR-MRA revealed one additional clinical finding, missed by FP-MRA. CONCLUSIONS An ECG- and navigator-gated HR-MRA-protocol with infusion of extracellular contrast agent at 3 Tesla is feasible. HR-MRA delivers significantly better image quality and vessel sharpness compared to FP-MRA. It may be integrated into a standard CMR-protocol for patients with CHD without the need for additional contrast agent injection and without any additional examination time.
منابع مشابه
First-pass and high-resolution ECG-gated MRA of the thoracic vasculature in children and adolescents using gadobutrol at 3 T
Introduction Using first-pass MRA (FP-MRA) spatial resolution is limited by breath-hold duration, and image quality (IQ) may be hampered by motion artefacts. Studies at 1.5 T have shown that the use of blood-pool contrast agents (BP-CA) allows for motion-compensated high-resolution MRA during the steady-state, yielding significantly higher IQ compared to FP-MRA. However, MRA with BP-CAs does no...
متن کاملCardiac MR imaging and MR angiography in pediatric congenital heart disease: a comparison between 1.5T and 3.0T
Background To assess the feasibility of cardiac magnetic resonance imaging (MRI) and angiography (MRA) at 3.0T in pediatric patients with congenital heart disease (CHD) and to compare the technical and diagnostic performance with an age-matched and clinically comparable control group imaged at 1.5T. Methods Forty-six patients (age 1 day to 8 years, mean 37.2 ± 32.8 months) with suspected or kno...
متن کامل4D Multiphase steady state imaging with contrast (MUSIC) enhancement using ferumoxytol: a new paradigm in pediatric congenital heart disease
Background CMR in children with congenital heart disease (CHD) often requires expert physician supervision and long examination times. Further, the complex anatomy may not be fully defined with limited 2D slices at the time of image acquisition and missing slice orientations cannot be reconstructed retrospectively. 4D MUSIC (1) generates isotropic high-resolution 3D images over multiple, indepe...
متن کاملBreath-hold imaging of the coronary arteries using quiescent-interval slice-selective (qiss) magnetic resonance angiography - pilot study at 1.5 tesla and 3 tesla
BACKGROUND Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enh...
متن کاملCongenital Heart Disease: Role of Time-Resolved MR Angiography
Background and Objective: Cardiac MRI and contrast-enhanced MR angiography (CE-MRA) are gaining interest as non-invasive diagnostic measures for both primary diagnosis and follow up of patients with congenital heart disease (CHD) (1). Due to the presence of complex anatomy and extensive collateral pathways between pulmonary and systemic circulation in patients with CHD, a highly temporally reso...
متن کامل