A simple and sensitive electrochemical immunosensor with impedance labelless detection and novel data processing method was investigated. One-step copolymerization was used to electrochemically deposit an antibody impregnated polypyrrole film on a glassy carbon electrode surface for the immunosensor. Impedance measurements provided a labelless or reporterless method to detect antibody (Ab)-antigen (Ag) interactions. Dimensionless analysis was employed to successfully process the measured impedance data. Since the method derived unit impedance change to eliminate or reduce the variation of the bulk electronic properties of Ab/polypyrrole films, the signal to noise ratio (S/N) was significantly improved for high sensitivity and specificity. Nonspecific binding effect was studied by array electrode chips and was found out that the polypyrrole electrode without antibody attachment had much stronger nonspecific binding effect than the Ab/polypyrrole electrode; incubation followed by thoroughly washing significantly reduced the nonspecific interference. 10 pg/ml detection limit and superior specificity were achieved by the method, demonstrating a highly sensitive labelless immunosensor in comparison with the detection limit of ng -microgram/ml for the reported polypyrrole based immunosensors. The electrochemical immunosensors presented in this paper, due to its simplicity, low cost, high sensitivity and superior specificity, could be an invaluable tool for clinical diagnostics and could have potential applications in drug discovery, environmental and food analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Frontiers in Bioscience 10, 2518-2526, September 1, 2005] 2518 IMPEDANCE LABELLESS DETECTION-BASED POLYPYRROLE PROTEIN BIOSENSOR

1. Abstract 2. Introduction 3. Materials and Methods 3.1. Materials and solutions 3.2. Apparatus 3.3. Experimental procedure 4. Result and discussion 4.1. Impedance detection of Ab-Ag (antibody-antigen) interactions 4.2. Data processing for S/N (signal to noise) ratio improvement 4.3. Specificity of impedance labelless detection of proteins 4.4. Nonspecific binding effect in serum sample 5. Con...

متن کامل

[Frontiers in Bioscience 10, ???, 1, 2005] IMPEDANCE LABELLESS DETECTION-BASED POLYPYRROLE DNA BIOSENSOR

Microelectrodes were fabricated to study impedance labelless detection of DNA hybridization. The probe molecule was attached onto the platinum microelectrode surface by electrochemically copolymerizing pyrrole and the probe oligonucleotides. Measured impedance complexes showed that an electrochemical redox-reaction occurred and the electrontransfer resistance increased after DNA hybridization. ...

متن کامل

[Frontiers in Bioscience 10, 180--186, January 1, 2005] 180 IMPEDANCE LABELLESS DETECTION-BASED POLYPYRROLE DNA BIOSENSOR

Microelectrodes were fabricated to study impedance labelless detection of DNA hybridization. The probe molecule was attached onto the platinum microelectrode surface by electrochemically copolymerizing pyrrole and the probe oligonucleotides. Measured impedance complexes showed that an electrochemical redox-reaction occurred and the electrontransfer resistance increased after DNA hybridization. ...

متن کامل

Modified Glass Carbon Electrode (GCE) Electropolymerized Polypyrrole Nanofibers with Hemoglobin (Hb) Film as a Unique Biosensor for Nitrite Determination

Abstract: In this study, we were investigated behavior the electrochemical reductionof nitrite at a hemoglobin (Hb) immobilized on glass carbon electrode (GCE) containingpolypyrol nanofiber (ppy) films. Polypyrrole (PPy) nanofibers have been constructed onGCE applying electrochemical technique, and can to deposit diverse polymers onminiaturized electrodes with this commo...

متن کامل

Development of Impedimetric Biosensor for Total Cholesterol Estimation Based on Polypyrrole and Platinum Nanoparticle Multi Layer Nanocomposite

A novel impedimetric biosensor was fabricated for total cholesterol sensing based on platinum nanoparticle and polypyrrole multilayer nanocomposite electrode. The Pt nanoparticles (PtNP) electrochemically deposited between two polypyrrole layers on indium tin oxide (ITO) glass plates (PtNP/PPY/ITO) have offered high-electroactive surface area and favourable microenvironment for immobilization o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Frontiers in bioscience : a journal and virtual library

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2005