Concentration dependencies of immunoturbidimetric dose-response curves: immunoturbidimetric titer and reactivity, and relevance to design of turbidimetric immunoassays.

نویسندگان

  • S Shahangian
  • K A Agee
  • R P Dickinson
چکیده

To characterize polyclonal antisera for two-point immunoturbidimetric applications, we defined, as functions of antiserum concentration, two parameters derived from dose-response curves: the maximum bichromatic optical response, Tmax, and the antigen concentration in the region of excess antibody corresponding to one-half Tmax, or C50. We raised monospecific polyclonal antisera in goats against several human immunoglobulins, C-reactive protein, C3, C4, apolipoproteins A-I and B, and several other proteins. We could linearly relate the logarithm of the antiserum concentration to log C50 and to log Tmax. The concentration of polyethylene glycol affected not only C50 and Tmax but also their functional dependencies on antiserum concentration. We devised two definitions of immunoturbidimetric titer and related them to the titer obtained by the single radial immunodiffusion method of Becker (Immunochemistry 1969; 6:539-46).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of plasma triglyceride concentrations on the accuracy of immunoturbidimetric assays of apolipoprotein B.

We have studied the influence of triglyceride-rich particles on the analytical bias of apolipoprotein B measurements by various immunoturbidimetric methods. Three commercially available methods grossly overestimate apolipoprotein B in samples with even moderately above-normal triglyceride concentrations. This effect is due to the increased relative reactivity of very-low-density lipoproteins in...

متن کامل

Influence of iron saturation as a possible source of error in the immunoturbidimetric determination of serum transferrin.

The serum transferrin concentration is usually overestimated when assessed as total iron binding capacity, because iron binds not only to transferrin but also, non-specifically, to other serum proteins [l-3]. Transferrin concentration can be measured directly by immunochemical methods including: radial immunodiffusion [ 1,2,4-61, immunonephelometric assay [6,7] and immunoturbidimetric assay [8,...

متن کامل

Immunoturbidimetric method for routine determinations of apolipoproteins A-I, A-II, and B in normo- and hyperlipemic sera compared with immunonephelometry.

We describe a method for routine immunoturbidimetry of apolipoproteins (apo) A-I, A-II, and B in both normo- and hyperlipemic sera. A special antiserum reagent, consisting of a highly concentrated mixture of nonionic and anionic detergents (final concentration in the assay, 36 g/L), rapidly removes intrinsic turbidities of even strongly lipemic sera without interfering with the antigen-antibody...

متن کامل

Validation of a commercially available automated canine-specific immunoturbidimetric method for measuring canine C-reactive protein

BACKGROUND Measurement of C-reactive protein (CRP) is used for diagnosing and monitoring systemic inflammatory disease in canine patients. An automated human immunoturbidimetric assay has been validated for measuring canine CRP, but cross-reactivity with canine CRP is unpredictable. OBJECTIVE The purpose of the study was to validate a new automated canine-specific immunoturbidimetric CRP meth...

متن کامل

Measurement of glycated hemoglobin A1c from dried blood by turbidimetric immunoassay.

BACKGROUND Glycated hemoglobin A1c (A1C) is an important marker in the diagnosis and treatment of diabetes. Dried blood measurement of A1C is useful in large scale epidemiological evaluation of A1C, especially to assess the impact of intervention programs. The possibility of using dried blood for measurement of A1C by the immunoturbidimetric method was explored in the present study. METHOD Bl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 6  شماره 

صفحات  -

تاریخ انتشار 1992