Perspectives on : Ion selectivity Design principles for K + selectivity in membrane transport

نویسندگان

  • Sameer Varma
  • David M. Rogers
  • Lawrence R. Pratt
  • Susan B. Rempe
چکیده

Please note that Yu et al. (2010. J. Amer. Chem. Soc. 132:10847–10856) cited the wrong LJ parameter set used for Na+ and K+ ions (Andersen, O.S., and B. Roux, personal communication). In their study, Yu et al. (2010) did not use the parameter set from Beglov and Roux (1994. J. Chem. Phys. 100:9050–9063), but instead the parameter set from Noskov and Roux (2008. J. Mol. Biol. 377:804–818). These two parameter sets yield different K+→Na+ hydration free energy differences. While the parameters from Beglov and Roux (1994) yield a value of −20.7 kcal/mol, the parameters from Noskov and Roux (2008) yield a value of −18.6 kcal/mol. This consequently modifies two entries in Table I (marked by asterisks below), but has no impact on the published conclusions. Correction

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SELECTIVE TRANSPORT AND EXTRACTION OF ALKALI METAL CATIONS (Na & K ) THROUGH CHLOROFORM LIQUID MEMBRANE BY DIETHYLENE GLYCOL MONOBUTYL ETHER AND DIETHYLENE GLYCOL DIBUTYL ETHER

A liquid membrane containing diethylene glycol monobutyl ether (2) shows specificity for K ion in transport while diethylene glycol dibutyl ether (1) was selective for Na over K . As an extractant, ligand 2 exhibited pronounced extraction selectivity for K over Na in comparison with ligand 1

متن کامل

Application of a dioxime-PVC electrode to potentiometric studies of Cr(III) ion

A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...

متن کامل

Enhancing Electrochemical Performance of Heterogeneous Cation Exchange Membranes by Using Super Activated Carbon Nanoparticles

Polyvinylchloride (PVC) based heterogeneous cation exchange membranes were prepared by the solution casting technique. The effect of super activated carbon nanoparticles concentration as filler additive in membrane matrix on ionic transfer behaviors of the membrane was studied. SOM images showed uniform particles distribution and relatively uniform surfaces for the membranes. The membrane water...

متن کامل

Determinants of cation transport selectivity: Equilibrium binding and transport kinetics

The crystal structures of channels and transporters reveal the chemical nature of ion-binding sites and, thereby, constrain mechanistic models for their transport processes. However, these structures, in and of themselves, do not reveal equilibrium selectivity or transport preferences, which can be discerned only from various functional assays. In this Review, I explore the relationship between...

متن کامل

PVC-Based Cerium Phosphate Membrane Exhibiting Selectivity for Molybdate Anions

A PVC-based membrane containing cerium phosphate was developed. Unlike the cerium phosphate itself that acts as a cation exchanger, the membrane exhibited anion-exchange properties. Therefore, the utility of this compound as a sensory element for detection of molybdate ions was pursued. The response of molybdate selective electrode based on this membrane was perfectly linear in the concentr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011