Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses.
نویسندگان
چکیده
BACKGROUND Metal ion toxicity, metal hypersensitivity, and metal carcinogenicity are causes for concern for patients with metal-on-metal hip replacements. Thus, understanding the biological fate of metal ions, and consequently their long-term systemic effects, is of great interest to patients and surgeons alike. METHODS Inductively coupled plasma mass spectrometry was used to measure the levels of cobalt, chromium, and molybdenum ions in the blood of control patients (preoperative control pre-resurfacing patients), patients with a metal-on-polyethylene total hip prosthesis, patients with a metal-on-metal total hip prosthesis with either a 28 or 36-mm femoral head, and patients with a hip resurfacing prosthesis. Since cobalt and chromium ions have the potential to induce oxidative stress through irreversible biochemical damage to macromolecules, the levels of ions were correlated to the concentration of three oxidative stress markers in the plasma of these patients. RESULTS The median cobalt level was significantly lower (p < 0.001) in the 36-mm metal-on-metal total hip arthroplasty group (1.8 parts per billion [1.8 microg/L]) compared with the 28-mm metal-on-metal total hip arthroplasty group (2.5 parts per billion [2.5 microg/L]) and the hip resurfacing group (2.3 parts per billion [2.3 microg/L]) at six months postoperatively. The median chromium level was also significantly lower (p < 0.01) in the 36-mm metal-on-metal total hip arthroplasty group (0.25 parts per billion [0.25 microg/L]) compared with the 28-mm metal-on-metal total hip arthroplasty group (0.35 parts per billion [0.35 microg/L]) and the hip resurfacing group (0.50 parts per billion [0.50 microg/L]) at six months postoperatively. However, neither the median cobalt levels nor the median chromium levels were significantly different among the three metal-on-metal groups at one year. The median levels of molybdenum were not significantly different among the three groups at either six months or one year. In addition, there was no significant difference in the plasma concentration of oxidative stress markers in patients with metal-on-metal bearings compared with that in control patients. CONCLUSIONS The blood metal ion levels in the hip resurfacing group were similar to those in the 28 and 36-mm-head metal-on-metal total hip arthroplasty groups. This study suggests that the increased metal ion levels had no effect on oxidative stress markers in the blood of these patients.
منابع مشابه
Metal ion levels decrease after revision for metallosis arising from large-diameter metal-on-metal hip arthroplasty.
Concerns have been renewed regarding the possible long-term effects of elevated circulating levels of cobalt and chromium as a direct result of implantation of large femoral head diameter metal-on-metal bearings. In order to establish whether metal ion levels remain persistently elevated, we compared metal ion levels before and after revision surgery in patients with large head diameter (greate...
متن کاملBrain structure and function in patients after metal-on-metal hip resurfacing.
BACKGROUND AND PURPOSE Hip prostheses that use a metal-on-metal articulation expose the brain to elevated metal concentrations that, in acute excess due to prosthesis malfunction, is associated with neurologic damage, including visual and hearing loss and motor deficits. Here, we examined whether chronic exposure to lower elevated metal levels, typical of well-functioning prostheses, also affec...
متن کاملOngoing problems with metal-on-metal hip implants.
Major advances in total hip replacement have occurred since the prosthesis was first developed by Charnley in the 1960s. Yet substantial concerns currently exist over newer hip implants as a result of rising revision rates and increased risk of cancer. By the 1980s revision rates of total hip replacements were as low as 20% after 15 years of follow-up. Throughout this era, the main focus was re...
متن کاملHip resurfacing versus metal-on-metal total hip arthroplasty - are metal ion levels different?
A systematic review and meta-analysis of trials comparing hip resurfacing to metal-on-metal total hip arthroplasty was conducted to determine if there is a difference in serum metal ion levels in patients receiving these implants. EMBASE and MEDLINE databases were searched from inception to December 2010 for all trials involving the use of these devices. Eligibility for inclusion in the review ...
متن کاملPseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging.
INTRODUCTION Many papers have been published recently on the subject of pseudotumors surrounding metal-on-metal hip resurfacing and replacement prostheses. These pseudotumors are sterile, inflammatory lesions within the periprosthetic tissues and have been variously termed masses, cysts, bursae, collections, or aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL). The prevalence o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 90 Suppl 3 شماره
صفحات -
تاریخ انتشار 2008