Dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma
نویسندگان
چکیده
BACKGROUND The purpose of this study was to compare carbon ion radiotherapy (C-ion RT) and stereotactic radiotherapy (SBRT) with photon beams for the treatment of hepatocellular carcinoma (HCC), specifically with regard to the dose volume parameters for target coverage and normal tissue sparing. METHODS Data of 10 patients who were treated using C-ion RT with a total dose of 60 Gy(RBE) in four fractions were used. The virtual plan of SBRT was simulated on the treatment planning computed tomography images of C-ion RT. Dose volume parameters such as minimum dose covering 90% of the planning target volume (PTV D90), homogeneity index (HI), conformity index (CI), mean liver dose (MLD), volume of the liver receiving 5 to 60 Gy (V5-60), and max point dose (Dmax) of gastrointestinal (GI) tract were calculated from both treatment plans. RESULTS The PTV D90 was 59.6 ± 0.2 Gy(RBE) in C-ion RT, as compared to 56.6 ± 0.3 Gy in SBRT (p < 0.05). HI and CI were 1.19 ± 0.03 and 0.79 ± 0.06, respectively in C-ion RT, as compared to 1.21 ± 0.01 and 0.37 ± 0.02, respectively in SBRT. Only CI showed a significant difference between two modalities. Mean liver dose was 8.1 ± 1.4 Gy(RBE) in C-ion RT, as compared to 16.1 ± 2.5 Gy in SBRT (p < 0.05). V5 to V50 of liver were higher in SBRT than C-ion RT and significant differences were observed for V5, V10 and V20. Dmax of the GI tract was higher in SBRT than C-ion RT, but did not show a significantly difference. CONCLUSIONS C-ion RT provides an advantage in both target conformity and normal liver sparing compared with SBRT.
منابع مشابه
Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies
Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...
متن کاملDosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study
Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...
متن کاملComparison of radiotherapy techniques to reduce hematologic toxicity in whole pelvic radiation therapy
Introduction: Concurrent chemoradiotherapy (CRT) is a standard treatment method for patients with carcinoma of cervix. Despite admirable therapeutic results, acute hematologic toxicity (HT) is common with this regimen. Many studies evaluate the relationship between the bone marrow dosimetric parameters and the severity of HT and result shown that the low dose of bone marrow wou...
متن کاملDosimetric comparison between XR-RV3 and EBT2 radiochromic film in megavoltage photon beams
Background: Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...
متن کاملDosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam
Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradiation in post‑lump...
متن کامل