Maps of time to maximum and time to peak for mismatch definition in clinical stroke studies validated with positron emission tomography.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Perfusion-weighted imaging-derived maps of time-to-maximum (Tmax) are increasingly used to identify the tissue at risk in clinical stroke studies (eg, DEFUSE and EPITHET). Using quantitative positron emission tomography (PET), we evaluated Tmax to define the penumbral flow threshold in stroke patients and compared its performance to nondeconvolved time-to-peak (TTP) maps. METHODS Comparative perfusion-weighted imaging and quantitative 15O-water PET images of acute stroke patients were analyzed using cortical regions of interest. A receiver-operating characteristic curve analysis described the threshold independent performance of Tmax (area under the curve) and identified the best threshold (equal sensitivity and specificity threshold) to identify penumbral flow (< 20 mL/100 g/min on PET cerebral blood flow). The results were compared with nondeconvolved TTP and other current perfusion-weighted imaging maps using the Mann-Whitney rank-sum test. RESULTS In 26 patients (time delay between MRI and PET, 65 minutes), the best threshold for penumbral flow was 5.5 seconds for Tmax (median; interquartile range, 3.9-6.6; sensitivity/specificity, 88%/89%). The area under the curve value was 0.95 (median; interquartile range, 0.93-0.97). Deconvolved Tmax did not perform significantly better than TTP (P = 0.34). CONCLUSIONS Maps of Tmax detected penumbral flow but did not perform better than the easy-to-obtain maps of nondeconvolved TTP. Thus, "simple" TTP maps still remain suitable for clinical stroke studies if detailed postprocessing is not feasible.
منابع مشابه
MRI perfusion maps in acute stroke validated with 15O-water positron emission tomography.
BACKGROUND AND PURPOSE Perfusion-weighted imaging maps are used to identify hypoperfusion in acute ischemic stroke. We evaluated maps of cerebral blood flow (CBF), cerebral blood volume, mean transit time, and time to peak (TTP) in acute stroke by comparison with positron emission tomography. METHODS Perfusion-weighted imaging and positron emission tomography were performed in 26 patients wit...
متن کاملA simple positron emission tomography-based calibration for perfusion-weighted magnetic resonance maps to optimize penumbral flow detection in acute stroke.
BACKGROUND AND PURPOSE Perfusion-weighted (PW) MRI is increasingly used to identify the tissue at risk. The adequate PW-MRI map and threshold remain controversial due to a considerable individual variation of values. By comparative positron emission tomography, we evaluated a simple MR-based and positron emission tomography-validated calibration of PW maps. METHODS PW-MRI and quantitative pos...
متن کاملMultiparametric Model for Penumbral Flow Prediction in Acute Stroke.
BACKGROUND AND PURPOSE Identification of salvageable penumbra tissue by dynamic susceptibility contrast magnetic resonance imaging is a valuable tool for acute stroke patient stratification for treatment. However, prior studies have not attempted to combine the different perfusion maps into a predictive model. In this study, we established a multiparametric perfusion imaging model and cross-val...
متن کاملCalculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit
Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...
متن کاملInfluence of the arterial input function on absolute and relative perfusion-weighted imaging penumbral flow detection: a validation with ¹⁵O-water positron emission tomography.
BACKGROUND AND PURPOSE Perfusion-weighted imaging maps are used to identify critical hypoperfusion in acute stroke. However, quantification of perfusion may depend on the choice of the arterial input function (AIF). Using quantitative positron emission tomography we evaluated the influence of the AIF location on maps of absolute and relative perfusion-weighted imaging to detect penumbral flow (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 41 12 شماره
صفحات -
تاریخ انتشار 2010