The impact of high pressure vs low pressure stent implantation on intimal hyperplasia and follow-up lumen dimensions; results of a randomized trial.
نویسندگان
چکیده
AIMS Histology and retrospective clinical studies have indicated that the amount of neointimal hyperplasia is dependent on the arterial injury induced during stent implantation. This study analysed, prospectively, the impact of high vs low pressure stent implantation techniques using a second generation stent on intimal hyperplasia and follow-up lumen dimensions. METHODS AND RESULTS Post-intervention and follow-up (mean[+/-SD] 5.5+/-1.3 months) angiographic and intravascular ultrasound studies were performed on 120 Multi-Link HP stents randomized to implantation at either low (8-10 atm) or high (16-20 atm) pressure. Intravascular ultrasound measurements of the external elastic membrane, stent, and lumen cross-sectional area were performed at 1 mm axial increments. Peri-stent plaque+media cross-sectional area (external elastic membrane-stent cross-sectional area, intimal hyperplasia cross-sectional area (stent-lumen cross-sectional area at follow-up), intimal hyperplasia thickness and peri-stent tissue growth cross-sectional area (Deltapersistent plaque+media cross-sectional area) were calculated. Intravascular ultrasound demonstrated a larger minimal lumen cross-sectional area post-intervention in the high pressure group (7.3+/-2.0 vs 6.2+/-1.8 mm(2), P<0.001, high vs low pressure group, respectively). At follow-up, the mean intimal hyperplasia cross-sectional area (1.7+/-0.9 vs 1.5+/-0.8 mm(2), P=0.708), the mean intimal hyperplasia thickness (0.16+/-0.12 vs 0.16+/-0.12 mm, P=0.818) and peri-stent tissue proliferation cross-sectional area were not greater in the high pressure group. Thus, the minimal lumen cross-sectional area at follow-up continued to be greater (5.5+/-2.0 vs 4.7+/-1.7 mm(2), P=0.038) in the high pressure group. CONCLUSIONS High pressure stent implantation results in greater stent expansion even with the less rigid second generation Multi-Link stent. Larger lumen dimensions persist at follow-up, while intimal hyperplasia is not significantly greater after high pressure implantation compared to the low pressure technique.
منابع مشابه
Impact of preinterventional arterial remodeling on neointimal hyperplasia after implantation of (non-polymer-encapsulated) paclitaxel-coated stents: a serial volumetric intravascular ultrasound analysis from the ASian Paclitaxel-Eluting Stent Clinical Trial (ASPECT).
BACKGROUND This study used serial volumetric intravascular ultrasound (IVUS) to evaluate the effect of preinterventional arterial remodeling on in-stent intimal hyperplasia (IH) after implantation of non-polymer-encapsulated paclitaxel-coated stents. METHODS AND RESULTS Patients were randomized to placebo or one of two doses of paclitaxel (low dose, 1.28 microg/mm2; high dose, 3.10 microg/mm2...
متن کاملStent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study.
AIMS Histological restenosis models in animals have indicated that stent design has a significant impact on vessel trauma during stent implantation and on the amount of subsequent neointimal tissue proliferation. The impact of different stent designs on intimal hyperplasia in human atherosclerotic coronary arteries has not been determined. METHODS AND RESULTS Angiographic and intravascular ul...
متن کاملA randomized, open-label clinical trial using optical coherence tomography to compare two sirolimus-eluting stents, one with a biodegradable polymer and the other with a permanent polymer.
Intimal hyperplasia appears to differ after implanting a drug-eluting stent (DES) with a biodegradable or a permanent polymer. The aim of the present study was to compare biodegradable with permanent polymer DES, since the available data are limited. One hundred patients with de novo coronary artery stenosis were included in this study. The patients were classified into 2 groups: DES with a bio...
متن کاملVolumetric analysis of in-stent intimal hyperplasia in diabetic patients treated with or without abciximab: results of the Diabetes Abciximab steNT Evaluation (DANTE) randomized trial.
BACKGROUND In diabetic patients in the Evaluation of Platelet IIb/IIIa Inhibitor for Stenting (EPISTENT) trial, abciximab reduced target vessel revascularization by approximately 50% compared with placebo. Whether this is a result of a lower restenosis rate caused by inhibition of intimal hyperplasia remains to be defined. METHODS AND RESULTS The purpose of this study was to determine whether...
متن کاملA double-blind, randomized, placebo-controlled multicenter clinical trial to evaluate the effects of the angiotensin II receptor blocker candesartan cilexetil on intimal hyperplasia after coronary stent implantation.
BACKGROUND Preclinical data suggest beneficial effects of angiotensin II receptor blockers (ARBs) on neointima formation after vascular injury. Preliminary clinical data, however, revealed conflicting results. The AACHEN trial was a double-blind, randomized, placebo-controlled clinical multicenter trial to evaluate the effects of candesartan cilexetil on intimal hyperplasia after coronary stent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European heart journal
دوره 22 21 شماره
صفحات -
تاریخ انتشار 2001