A mechanical and computational investigation on the effects of conduit orientation on the strength of massive bone allografts.
نویسندگان
چکیده
Structural bone allografts are used to reconstruct large skeletal defects resulting from trauma, tumor resection, or revision arthroplasty. Though used for over a century, bone allografts suffer from a high rate of mechanical failure due to limited graft revitalization even after extended periods in vivo. The current study evaluated the mechanical properties of longitudinally perforated cortical bone allografts (LAP) that have been shown to promote accelerated graft incorporation in a large animal model. The compressive and tensile properties of longitudinally perforated allograft specimens, as determined through uniaxial compression and diametral compression tests, respectively, were not significantly affected by the presence of the conduit. However, transversely perforated grafts (TAP) demonstrated a marked decrease in tensile capacity (p=0.04). Finite element analysis demonstrated moderate increases in the maximum principal stresses in LAP specimens while TAP models indicated an 83.4% increase in maximum principle stress near the conduit on the endosteal surface of the graft. This research and the previous in vivo study suggest that LAP adequately serves as an internal template within the cortical bone allograft for osseous apposition and revitalization without adversely affecting the structural or mechanical integrity of the graft.
منابع مشابه
An investigation of the effects of osteoporosis, impact intensity and orientation on human femur injuries: a parametric finite element study
Objective: Femur is the strongest, longest and heaviest bone in the human body. Due to the great importance of femur in human body, its injury may cause large numbers of disabilities and mortality. Considering various effective parameters such as mechanical properties, geometry, loading configuration, etc. can propel the study to the trustable results.. Methods: A 3D finite element model of the...
متن کاملAn investigation of tensile strength of Ti6Al4V titanium screw inside femur bone using finite element and experimental tests
The geometric optimization of orthopedic screws can considerably increase their orthopedic efficiency. Due to the high geometric parameters of orthopedic screws, a finite element simulation is an effective tool for analyzing and forecasting the effect of the parameters on the load-bearing capacity of different types of screws and bones. Thus, in the present study, the tensile strength of a typi...
متن کاملIn vitro and In vivo Investigation of poly(lactic acid)/hydroxyapatite nanoparticle scaffold containing nandrolone decanoate for the regeneration of critical-sized bone defects
Objective(s): Bone tissue engineering is aimed at the fabrication of bone graft to ameliorate bone defects without using autografts or allografts. Materials and Methods: In the present study, the coprecipitation method was used to prepare hydroxyapatite (HA) nanoparticles containing nandrolone. To do so, 12.5, 25, and 50 mg of nandrolone were loaded into poly(lactic acid) (PLA)/nano-HA, a...
متن کاملAn investigation on Mechanical Properties of Apatite-Wollastonite-Diopside Glass-Ceramics Composites
Apatite-wollastonite (A-W)-phlogopite glass-ceramic is considered to be difficult to resorb, but often, it has been incorporated in particulate form to create new bioactive composites for potential maxillofacial applications. With various compositions, the present work has attempted to prepare apatite-wollastonite (A-W)-phlogopite glass ceramic composites, by applying sintering. Here, three-poi...
متن کاملThe early results of massive osteoarticular allograft in the surgical treatment of lower limb bone tumors
This is the early results of 20 cases of massive osteoarticular allograft performed for reconstruction of lower limb s after resection of bone tumors. These cases include 7 distal femur and hemiarticular ,6 proximal tibio and hemiarticular, 3 total knee joints and 4 proximal femur with total hip replacement. Bone allografts were taken at steril condition from early postmortum cadavers and st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bone
دوره 41 5 شماره
صفحات -
تاریخ انتشار 2007