Comparative evaluation of three commercial tests for detection of heterophile antibody in patients with infectious mononucleosis.
نویسندگان
چکیده
Infectious mononucleosis (IM) is caused by the Epstein-Barr virus. Commonly used laboratory tests used for diagnosis of IM include a screening test based on the observation that horse erythrocytes are agglutinated by the Paul-Bunnell antibody found in the serum of patients with IM. This study evaluated two latex agglutination (LA) kits for IM, Monolatex (Wampole Laboratories) and Immunoscan-IM (American MicroScan) (formerly Monogen; Biokit, S.A.), and compared them with Monospot (Ortho Diagnostic Systems) results on 220 patient sera. Discrepancies in the three test results were resolved with complete Epstein-Barr virus antibody profiles. They indicated that any of the three kits tested can be successfully used as a screening test for IM. The advantage of the LA kits is that no differential absorption step is necessary. When discrepancies were resolved, sensitivity and specificity of both LA kits were greater than 93%.
منابع مشابه
An evaluation of the Monosticon rapid slide test diagnosis of infectious mononucleosis.
A new rapid slide test for the detection of infectious mononucleosis heterophile antibody has been compared with the Paul-Bunnell absorption test. Out of 200 sera, 46 were seropositive for infectious mononucleosis by the Paul-Bunnell test and 43 of these were detected by the Monosticon test; the three Monosticon-negative sera were of low titre. There was no problem with false positive reactions...
متن کاملEvaluation of a novel dry latex preparation for demonstration of infectious mononucleosis heterophile antibody in comparison with three established tests.
A new, dried antigen-coated latex preparation for the demonstration of infectious mononucleosis (IM) heterophile antibody (Dryspot IM kit; Oxoid, Ltd., Basingstoke, Hampshire, United Kingdom) was compared with the IM kit (a liquid latex reagent from the same source), an immunoassay (ImmunoCard Mono; Meridian Diagnostics), and an absorption test (Monospot; Meridian Diagnostics). The latter was u...
متن کاملHorse erythrocyte glycoprotein-latex reagent that reacts with infectious mononucleosis heterophile antibody.
A sialoglycoprotein from horse erythrocytes was isolated in essentially homogeneous form and found to contain the neuraminidase-sensitive determinant of the horse erythrocyte for Paul-Bunnell heterophile antibodies of infectious mononucleosis. This reactivity was retained after covalent coupling of the antigen to latex particles. The latex reagent has greater stability (greater than 3 years) th...
متن کاملA rapid slide test for heterophile antibody in infectious mononucleosis.
‘SINCE the discovery by Paul and BunnelP in 1932. of the presence of heterophile . antibodies in the sera of patients with infectious mononucleosis, there has been a great deal of investigation into the nature and production of anti-sheep red cell aggulutinins.’ With the advent of the Rh factor and the subsequent discovery of blocking3 (incomplete,4 or hyperimmune5) antibody new avenues of appr...
متن کاملHematologic differences in heterophile-positive and heterophile-negative infectious mononucleosis.
Infectious mononucleosis (IM) due to all causes is characterized by atypical lymphocytosis. We sought to compare hematologic parameters of infectious mononucleosis due to Epstein-Barr virus (EBV) infection (heterophile antibody (HA) positive) with mononucleosis due to other causes. Mono-Latex Slide Agglutination Test results and complete blood counts (CBC) of 147 patients with mononucleosis wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 26 2 شماره
صفحات -
تاریخ انتشار 1988