Weight-based, low-dose pediatric whole-body PET/CT protocols.

نویسندگان

  • Adam M Alessio
  • Paul E Kinahan
  • Vivek Manchanda
  • Victor Ghioni
  • Lisa Aldape
  • Marguerite T Parisi
چکیده

UNLABELLED Adult PET/CT acquisition protocols need to be modified for pediatric imaging to minimize the radiation dose while maintaining diagnostic utility. We developed pediatric PET/CT acquisition protocols customized to patient weight and estimated the dosimetry and cancer risk of these low-dose protocols to communicate basic imaging risks. METHODS Protocols were developed for whole-body (18)F-FDG imaging of patients in PET mode with a weight-based injected activity (5.3 MBq/kg) and acquisition times (3-5 min/field of view) and for CT for attenuation correction and localization with a weight-based tube current ranging from 10 to 40 mAs. Patients were categorized on the basis of the Broselow-Luten color-coded weight scale. Dosimetry and radiation-induced cancer risk for the PET and CT acquisition in each category were derived from mean patient sizes and the interpolation of factors from accepted patient models. RESULTS Whole-body pediatric PET/CT protocols require the customization of PET-acquisition settings and task-specific selection of CT technique. The proposed weight-based protocols result in an approximate effective dose ranging from 8.0 mSv for a 9-kg patient up to 13.5 mSv for a 63-kg patient. The radiation dose from the proposed protocols is 20%-50% (depending on patient weight), the dose from PET/CT protocols that use a fixed CT technique of 120 mAs and 120 kVp. The approximate, conservative estimate of additional lifetime attributable risk (LAR) of cancer incidence for females using the proposed protocols was approximately 3 in 1,000, with a variation of 18% across patient categories. For males, the additional LAR of cancer incidence was approximately 2 in 1,000, with a variation of 16% across categories. CONCLUSION Low-dose PET/CT protocols for 11 patient weight categories were developed. The proposed protocols offer an initial set of acquisition parameters for pediatric PET/CT. The use of multiple categories allows for the continued refinement of dose-reduction parameters to minimize dose while maintaining image quality across the range of pediatric patient sizes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

Estimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom

One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...

متن کامل

Radiation exposure of patients undergoing whole-body dual-modality 18F-FDG PET/CT examinations.

UNLABELLED We investigated radiation exposure of patients undergoing whole-body 18F-FDG PET/CT examinations at 4 hospitals equipped with different tomographs. METHODS Patient doses were estimated by using established dose coefficients for 18F-FDG and from thermoluminescent measurements performed on an anthropomorphic whole-body phantom. RESULTS The most relevant difference between the proto...

متن کامل

JOURNAL CLUB: CT dose optimization for whole-body PET/CT examinations.

OBJECTIVE. The objective of this study was to optimize CT protocols for whole-body PET/CT by reducing radiation dose while minimizing effects on image quality. MATERIALS AND METHODS. Before protocol optimization, a survey of 140 consecutive patients was conducted to establish the baseline dose from a whole-body PET/CT examination. Another sample of 100 patients was surveyed to evaluate the redu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 50 10  شماره 

صفحات  -

تاریخ انتشار 2009