Thoracic Tumor Volume Delineation in 4D-PET/CT by Low Dose Interpolated CT for Attenuation Correction

نویسندگان

  • Tzung-Chi Huang
  • Yao-Ching Wang
  • Chia-Hung Kao
چکیده

PURPOSE 4D-PET/CT imaging is an excellent solution for reducing the breathing-induced effects in both CT and PET images. In 4D-PET/CT, 4D-CT images are selected to match those of 4D-PET phase by phase and the corresponding phases are used for attenuation correction in 4D-PET. However, the high radiation dose that patients acquire while undergoing 4D-CT imaging for diagnostic purposes remains a concern. This study aims to assess low-dose interpolated CT (ICT) for PET attenuation correction (PETICT) in thoracic tumor volume delineation. METHODS AND MATERIALS Twelve thoracic cancer patients (10 esophageal and 2 lung cancer cases) were recruited. All patients underwent 4D-PET/CT scans. The optical flow method based on image intensity gradient was applied to calculate the motion displacement in three dimensions for each voxel on two original extreme CT phases in the respiratory cycle, end-inspiration and end-expiration. The interpolated CTs were generated from two phases of the original 4D-CT using motion displacement. RESULTS Tumor motion due to respiration was estimated in the anterior-posterior dimension, the lateral dimension and the superior-inferior dimension by the optical flow method. The PETICT and ICT (4D-PET ICT/ICT) matched each other spatially in all the phases. The distortion of tumor shape and size resulting from respiratory motion artifacts were not observed in 4D-PETICT. The tumor volume measured by 4D-PET ICT/ICT correlated to the tumor volume measured by 4D-PET/CT (p = 0.98). CONCLUSIONS 4D-PETICT consistently represented the interpretation of FDG uptake as effectively as 4D-PET. 4D-PET ICT/ICT is a low-dose alternative to 4D-CT and significantly improves the interpretation of PET and CT images, while solving the respiratory motion problem as effectively as 4D-PET/CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of Internal Tumor Volumes of Non-Small Cell Lung Cancer Patients for Radiation Treatment Planning Using Interpolated Average CT in PET/CT

Respiratory motion causes uncertainties in tumor edges on either computed tomography (CT) or positron emission tomography (PET) images and causes misalignment when registering PET and CT images. This phenomenon may cause radiation oncologists to delineate tumor volume inaccurately in radiotherapy treatment planning. The purpose of this study was to analyze radiology applications using interpola...

متن کامل

Estimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom

One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...

متن کامل

Comparison of PET/CT and CT-based tumor delineation and its effects on the radiation treatment planning for non-small cell lung cancer

Introduction: Tumor volume delineation is the most important step in the radiation treatment planning. In this study the impact of PET/CT data on the tumor delineation precision of non-small cell lung cancer (NSCLC) was investigated. Methods: PET/CT images of 20 patients with primary NSCLC were obtained and imported to the treatment planning system for im...

متن کامل

Low dose interpolated average CT for thoracic PET/CT attenuation correction using an active breathing controller.

PURPOSE The temporal mismatch between PET and standard helical CT (HCT) causes substantial respiratory artifacts in PET reconstructed images when using HCT as the attenuation map. Previously we developed an interpolated average CT (IACT) method for attenuation correction (AC) and demonstrated its merits in simulations. In this study we aim to apply IACT in patients with thoracic lesions using a...

متن کامل

Contribution of 68Ga-PSMA PET/CT to targeting volume delineation of prostate cancer treated with conformal radiation therapy: Which SUV threshold is appropriate?

Introduction: Prostate-specific membrane antigen (PSMA) has been demonstrated as a promising tool for specific imaging of prostate cancer (PCa) via positron emission tomography-computed tomography (PET/CT) scanning. Radiation treatment planning (RTP) based on 68Ga-PSMA PET/CT scanning can also lead to some decision modifications.  The specific goal o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013