Recanalisation of an occluded modified Blalock-Taussig shunt by balloon dilatation.
نویسندگان
چکیده
A four year old boy with pulmonary atresia and ventricular septal defect had an acute cyanotic episode three years after undergoing a right-sided, 6 mm diameter, modified Blalock-Taussig shunt. On admission no continuous murmur could be heard from the shunt and the typical high velocity, continuous flow profile of the shunt could not be identified by Doppler echocardiography. At catheterisation a right subclavian artery angiogram confirmed shunt occlusion. From the subclavian artery, an 0.035 inch wire was used to enter the occluded shunt and then the pulmonary artery. Balloon angioplasty of the entire length of the shunt was performed with 6 mm diameter balloon. After angioplasty the arterial oxygen saturation increased from 63% to 83%. The patient was treated with intravenous heparin followed by warfarin. Repeat catheterisation and angiography eight days later confirmed wide patency of the shunt.
منابع مشابه
Blalock - Taussig shunt . modified ( polytetrafluoroethylene ) Balloon dilatation of a stenosed
A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence ofproximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months la...
متن کاملBalloon dilatation of a stenosed modified (polytetrafluoroethylene) Blalock-Taussig shunt.
A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence of proximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months l...
متن کاملRecanalization of a discrete atretic right pulmonary artery segment with a new radiofrequency system.
We describe a case in which a discrete atretic segment of the right pulmonary artery (due to a Blalock-Taussig shunt) was reconstructed using a new radiofrequency system, balloon dilation, and stent implantation in an 18-month-old patient. The shunt was coil-occluded. The technique and applications of this novel approach are discussed.
متن کاملTranscatheter occlusion of a Blalock-Taussig shunt with a detachable balloon in a child.
A case of transcatheter occlusion of a Blalock-Taussig shunt with a detachable silicone filled balloon is described. This 11 year old boy had previously had a repair of tetralogy of Fallot together with ligation of a large Blalock-Taussig shunt. Though there was a good surgical result, the shunt proved to be incompletely closed leaving a significant left to right shunt. As an alternative to a f...
متن کاملComplications of modified Blalock-Taussig shunts mimicking pulmonary disease.
The modified Blalock-Taussig shunt is commonly performed as early palliation in cyanotic congenital heart disease. To highlight unusual diagnostic problems in such patients, two cases are reported in whom shunt complications were initially diagnosed as lobar pneumonia and tuberculosis, respectively. The children, an 8 month old boy and a 3 year old boy, had false aneurysm secondary to infection...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 70 5 شماره
صفحات -
تاریخ انتشار 1993