New semiquantitative assessment of 123I-FP-CIT by an anatomical standardization method.

نویسندگان

  • Seiko Takada
  • Mana Yoshimura
  • Hiroaki Shindo
  • Kazuhiro Saito
  • Kiyoshi Koizumi
  • Hiroya Utsumi
  • Kimihiko Abe
چکیده

UNLABELLED We evaluated a new semiquantitative procedure to more easily and objectively estimate the striatal uptake of 123I-FP-CIT in patients with Parkinsonian syndrome (PS) and essential tremor (ET), using an anatomical standardization method, the Neurostat. METHODS Eleven patients with PS and 8 with ET were examined by clinical assessment and 123I-FP-CIT SPECT imaging. The modified Hoehn and Yahr Staging Scale and Unified Parkinson's Disease Rating Scale (UPDRS) were used to assess the stage and severity of the disease. The co-registered MR and SPECT images were created with fusion software included in Neurostat. On the cross section, which shows the largest area of striate, irregular shaped regions of interest corresponding to the striate and occipital cortex were drawn. Then the ratio of specific striatal uptake to non-specific occipital cortex, V3"(F), was calculated. Another calculation was done by VOIClassic, which is a software included in Neurostat to estimate the counts per voxel of anatomically defined regions such as caudate nucleus, putamen, occipital cortex, and total cortex. Using these count data, the ratio of specific striatal uptake to non-specific occipital cortex, V3"(OC), and total cortex, V3"(TC), was calculated. RESULTS A fair linear correlation was observed between V3"(OC) and V3"(F) (y = 1.53x + 1.40; r = 0.756; p < 0.01), as well as between V3"(TC) and V3"(F) (y = 1.24x + 1.43; r = 0.713; p < 0.01). Both V3"(OC) and V3"(TC) yielded similar tendencies. Concerning discrimination between ET and PS, there was a significant difference between the mean V3" of PS and ET (p < 0.01). Concerning the correlation between V3" value and the severity of PS, the UPDRS motor score significantly correlated with the V3"(F) value (rs = -0.816). However, V3"(OC) and V3"(TC) correlated less with UPDRS (rs = -0.667 and -0.645, respectively). CONCLUSIONS Semiquantitative parameters, V3"(OC) and V3"(TC), calculated by VOIClassic including the Neurostat system are useful and easily calculable parameters as well as V3"(F) for the differential diagnosis of PS from ET.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database

Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...

متن کامل

Accurate differentiation of parkinsonism and essential tremor using visual assessment of [123I]-FP-CIT SPECT imaging: the [123I]-FP-CIT study group.

OBJECTIVE To evaluate whether visual assessment of [123I]-FP-CIT (DaTSCAN, Nycomed Amersham, plc) single photon emission computerized tomography (SPECT) images can differentiate between parkinsonism and essential tremor (ET). METHODS [123I]-FP-CIT SPECT imaging was conducted in a six-center study of 158 patients with a clinical diagnosis of parkinsonism compared with 27 ET cases and 35 health...

متن کامل

Autopsy validation of 123I-FP-CIT dopaminergic neuroimaging for the diagnosis of DLB

OBJECTIVE To conduct a validation study of 123I-N-fluoropropyl-2b-carbomethoxy-3b-(4-iodophenyl) nortropane (123I-FP-CIT) SPECT dopaminergic imaging in the clinical diagnosis of dementia with Lewy bodies (DLB) with autopsy as the gold standard. METHODS Patients >60 years of age with dementia who had undergone 123I-FP-CIT imaging in research studies and who had donated their brain tissue to th...

متن کامل

Validation of Optimum ROI Size for 123I-FP-CIT SPECT Imaging Using a 3D Mathematical Cylinder Phantom

Objective(s): The partial volume effect (PVE) of single-photon emission computed tomography (SPECT) on corpus striatum imaging is caused by the underestimation of specific binding ratio (SBR). A large ROI (region of interest) set using the Southampton method is independent of PVE for SBR. The present study aimed to determine the optimal ROI size with contrast and SBR for striatum images and val...

متن کامل

Diagnostic Accuracy of Parkinson Disease by Support Vector Machine (SVM) Analysis of 123I-FP-CIT Brain SPECT Data

Brain single-photon-emission-computerized tomography (SPECT) with I-ioflupane (I-FP-CIT) is useful to diagnose Parkinson disease (PD). To investigate the diagnostic performance of I-FP-CIT brain SPECT with semiquantitative analysis by Basal Ganglia V2 software (BasGan), we evaluated semiquantitative data of patients with suspect of PD by a support vector machine classifier (SVM), a powerful sup...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 20 7  شماره 

صفحات  -

تاریخ انتشار 2006