A decade of development in immunoassay methodology.
نویسنده
چکیده
Immunoassays are now very widely used in the clinical laboratory, either because no other type of assay system is feasible or because they are often the most effective and suitable of the possible analytical methods. The last decade has seen the development and refinement of many new immunoassay reagents and systems. The major trend has been away from liquid-phase assays involving radioisotopic labels, towards fast homogeneous or solid-phase assays capable of operation anywhere; and towards precise and reliable nonisotopic, automated or semi-automated laboratory assays, often with detection limits measured in pico- or attomoles. The use of monoclonal antibodies is now widespread, and the methodologies of labels and of solid-phase components are much more sophisticated. New assay formulations, novel homogeneous systems, immunosensors, free-analyte assays, the importance of thorough validation and of interfering substances, and future trends are discussed.
منابع مشابه
Development of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies
Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...
متن کاملDevelopment of a Latex Agglutination Method for Diagnosis of Rotavirus Infections
Background: Rotavirus is a major cause of morbidity and mortality among children with gastroenteritis. Since the discovery of rotaviruses, several techniques have been used for their laboratory diagnosis; those included Electron Microscopy (EM) and enzyme immunoassay. These methods, however, are expensive and not readily available everywhere. We have developed a technique which can be used for ...
متن کاملNew Concept in Leanness Development and Assessment in Plant Life Cycle (PLC)
Abstract: At the last decade of the 20th century, Womack et. Al introduced Lean concept to the industrial world. Since 1990 up to now, existed studies mostly have focused on lean production in the step of manufacturing, but in this research leanness concept has developed in the plant life cycle. In this paper leanness concept will be described as elimination of wastes in the phases of investmen...
متن کاملNEW CONCEPT IN LEANNESS DEVELOPMENT AND ASSESSMENT IN PLANT LIFE CYCLE (PLC)
At the last decade of the 20th century, Womack et. Al introduced Lean concept to the industrial world. Since 1990 up to now, existed studies mostly have focused on lean production in the step of manufacturing, but in this research leanness concept has developed in the plant life cycle. In this paper leanness concept will be described as elimination of wastes in the phases of investment, plant d...
متن کاملDevelopment of antibody-based microarray assay for quantitative detection of aflatoxin B1
BACKGROUND: Aflatoxin B1 (AFB1) is a toxic metaboliteproduced by Aspergillus species that contaminates a wide range ofagricultural products. OBJECTIVES: This study was designed todevelop a rapid and highly sensitive immunoassay method inmicroarray format for quantitative detection of AFB1 to evaluatethe potential of microarray platform for high-throughput screening,which can be beneficial in fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 36 8 Pt 1 شماره
صفحات -
تاریخ انتشار 1990