Factors Associated With Corneal Deformation Responses Measured With a Dynamic Scheimpflug Analyzer.

نویسندگان

  • Atsuya Miki
  • Naoyuki Maeda
  • Yasushi Ikuno
  • Tomoko Asai
  • Chikako Hara
  • Kohji Nishida
چکیده

Purpose The purpose of this study was to clarify correlations between corneal deformation parameters measured with a dynamic Scheimpflug analyzer and baseline factors such as axial length, intraocular pressure (IOP), age, central corneal thickness (CCT), and corneal curvature. Methods Ninety-six eyes of 96 healthy subjects (mean 55.2 ± 16.1 years of age) were examined using a dynamic Scheimpflug analyzer. Eighteen of 35 deformation parameters were selected for analyses based on measurement reliability and clinical relevance. The associations between corneal deformation parameters and axial length, IOP, age, CCT, and average corneal power were evaluated using multivariate regression analyses. Results Deformation parameters were correlated significantly with axial length (n = 13), IOP (n = 13), age (n = 8), and CCT (n = 6) in the multivariate models. Longer axial length corresponded with greater corneal deformability, less viscous damping, and less movement of the entire eye. Higher IOP was associated with greater corneal resistance and less movement of the entire eye. Older age was associated with less corneal deformability and greater movement of the entire eye. Corneal curvature was correlated significantly with only three deformation parameters. Conclusions This study clarified the substantial impact of axial length, age, and IOP on the biomechanical responses of the cornea and the entire eye. In contrast, corneal curvature did not affect most of the deformation parameters. The current results confirmed the importance of corneal biomechanics, especially in eyes with longer axial length and in older subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An ultra-high-speed Scheimpflug camera for evaluation of corneal deformation response and its impact on IOP measurement.

PURPOSE To investigate the test-retest variability of and factors associated with the corneal deformation response, and evaluate its impact on IOP measurement. METHODS Forty normal and 140 glaucoma suspect/glaucomatous eyes of 104 individuals were prospectively included for repeated measurements of corneal deformation response by an ultra-high-speed Scheimpflug camera, followed by corneal hys...

متن کامل

Impact of chamber pressure and material properties on the deformation response of corneal models measured by dynamic ultra-high-speed Scheimpflug imaging.

PURPOSE To study the deformation response of three distinct contact lenses with known structures, which served as corneal models, under different chamber pressures using ultra-high-speed (UHS) Scheimpflug imaging. METHODS Three hydrophilic contact lenses were mounted on a sealed water chamber with precisely adjustable pressure: TAN-G5X (41% hydroxyethylmethacrylate/glycolmethacrylate, 550 µm ...

متن کامل

Corneal Biomechanical Properties in Myopic Eyes Measured by a Dynamic Scheimpflug Analyzer

Purpose. To evaluate the corneal biomechanical parameters in myopic and emmetropic eyes using Corneal Visualization Scheimpflug Technology (CorVis ST). Methods. 103 myopic and emmetropic eyes of 103 patients were examined. Corneal biomechanical parameters, axial length, and mean keratometry were measured using CorVis ST, IOL Master, and topography, respectively. Corneal biomechanical properties...

متن کامل

Comparative Evaluation of Elevation, Keratometric, Pachymetric and Wavefront Parameters in Normal Eyes, Subclinical Keratoconus and Keratoconus with a Dual Scheimpflug Analyzer

Purpose: To compare the corneal parameters in normal corneas, forme fruste keratoconus (FFKC) and keratoconus measured with a dual Scheimpflug analyzer. Materials and methods: A total of 372 eyes of 197 patients were prospectively enrolled in the study and divided into three groups: 148 eyes of 102 patients with keratoconus, 47 contralateral topographically normal eyes of clinically evident ker...

متن کامل

Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism.

PURPOSE To evaluate the impact of posterior corneal astigmatism on outcomes with toric intraocular lenses (IOLs). SETTING Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. DESIGN Case series. METHODS Corneal astigmatism was measured using 5 devices before and 3 weeks after cataract surgery. Toric IOL alignment was recorded at surgery and at the slitlamp 3 weeks postop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 2017