A study of CO sensors with oscillatory response
نویسندگان
چکیده
In this paper, oscillatory changes in the conductance of catalyst-doped SnO2 semiconductor materials in the presence of CO gas are investigated. The sensors with various transducing structures of ceramic tubes (Taguchi structure), co-axial Pt coils and substrates with deposited interdigital electrodes are compared. The results show that catalysts in the sensing materials and the sensor’s operating temperature play a key role in generating an oscillatory response. A unique oscillatory response is observed when a bare Pt coil is exposed to CO gas. The relationship between the oscillation waveforms, gas concentration, operating conditions and gas flow rates for the Pt coils are preliminarily tested and discussed. © 2003 Elsevier B.V. All rights reserved.
منابع مشابه
Adsorption of Gas Molecules on Graphene Doped with Mono and Dual Boron as Highly Sensitive Sensors and Catalysts
First-principle calculations have been investigated to study the adsorption of the molecules (SO2, CO, NH3, CO2, NO2, and NO) on the surface of mono boron (B) B-doped and dual B-doped graphene sheets to explore their potential applications as sensors. Our findings indicate that the adsorption of (CO and NH3) on B-doped graphene and (CO and ...
متن کاملParametric study of a novel oscillatory wind turbine
Clean energy harvesting and usage has gained considerable attention in the last few decades. While the horizontal axis wind turbines have been used extensively, they have certain defects and functional limitations. In the present paper, a novel oscillatory wind turbine is proposed. The conceptual design of the new turbine together with its configuration is explained. Dynamical equations of the ...
متن کاملIon Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation
Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The...
متن کاملDetermination of Chromium(III) and Magnesium(II) Ions in Pharmacological and Real Water Samples using Potentiometric Sensors based on Chitosan Schiff base Derivative as Green and Sensitive Ionophore
In the study, novel and sensitive carbon paste electrodes (CPEs) developed for thepotentiometric measurement of Cr(III) and Mg(II) ions in pharmacological and water samples.CPEs as indicator electrodes were prepared from a mixture of four components, includinggraphite powder, paraffin oil, multi-walled carbon nanotubes (MWCNTs), and a greenionophore (Chitosan Schiff base...
متن کاملGreen Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes
Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003