Monocyte counting: discrepancies in results obtained with different automated instruments.
نویسندگان
چکیده
To determine the accuracy of several methods for measuring the monocyte count, the results obtained by a number of different automated cell counters were analysed. Considerable discrepancies occurred for monocyte counts obtained in normal blood among the counters. The results of a visual monocyte count on a total of 800 leucocytes were used as the reference method. The technique of measuring the monocyte count by using dual staining with monoclonal antibodies CD45 and CD14 provided the closest agreement with the reference method. Six other automated counting systems were assessed. Two of these systems (Coulter VCS and Technicon H1) gave results, which, although under-estimating monocytosis, correlated well with the results obtained by the reference technique. A third system (Toa Sysmex NE-8000) gave unreliable results. Three of the automated systems evaluated measured a "third population"--that is, monocytes together with other leucocytes. One of these systems (Ortho ELT 1500), overestimated the count, as expected, but correlated well with the reference method. The second of these "third population counters" (Coulter S Plus IV) correlated moderately well with the reference monocytosis, while the Toa Sysmex E-5000 correlated poorly. It is clear that problems exist in the evaluation of different instruments for counting monocytes. An accurate and reliable reference method is a pre-requisite to evaluate this aspect of cell counters. As the visual method is too cumbersome a different reference method would be useful. Based on the results of this study, it is suggested that the technique using fluorescence labelled monoclonal antibodies should be regarded as an acceptable alternative.
منابع مشابه
Comparison between semi-automated segmentation and manual point-counting methods for quantitative analysis of histological sections.
The aim of the present study was to compare results obtained using the manual point-counting method with results obtained using the semi-automated segmentation method, in the quantitative evaluation of histological sections by light microscopy. The tongues of 40 rats (Ratus norvergicus) were processed using the paraffin technique, in which a 5-mum-thick tissue slice cut from each tongue is stai...
متن کاملIs automated platelet counting still a problem in thrombocytopenic blood?
CONTEXT Reliable platelet counting is crucial for indicating prophylactic platelet transfusion in thrombocytopenic patients. OBJECTIVE To evaluate the precision and accuracy of platelet counting for thrombocytopenic patients, using four different automated counters in comparison with the Brecher & Cronkite reference method recommended by the International Committee for Standardization in Hema...
متن کاملValidity of Selected WBC Differentiation Flags in Sysmex XT-1800i
Background: Automatic Cell Counter devises make the CBC differential very easy and delivering the results in few second. However, the problem with this device is facing a flag requires a time-consuming microscopic review of the specimen which causes unacceptable wait times for patient as well as costs for laboratories. In this study, we calculated the validity of WBC d...
متن کاملمقایسه شمارش خودکار با شمارش دستی نوتروفیلها در تشخیص پریتونیت باکتریال خود به خودی
Introduction: Spontaneous bacterial peritonitis (SBP) is a prevalent complication in the patients with cirrhosis and ascites, which leads to high intrahospital mortality. Diagnosis is made when ascetic fluid neutrophils is ≥250 cells/mm3. Manual counting of neutrophils is time-consuming, technically difficult, expensive and in many cases individual-dependent. In contrast, automated counting ...
متن کاملFace Detection with methods based on color by using Artificial Neural Network
The face Detection methodsis used in order to provide security. The mentioned methods problems are that it cannot be categorized because of the great differences and varieties in the face of individuals. In this paper, face Detection methods has been presented for overcoming upon these problems based on skin color datum. The researcher gathered a face database of 30 individuals consisting of ov...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 44 3 شماره
صفحات -
تاریخ انتشار 1991