Reference intervals of echocardiographic measurements in healthy adult dairy goats

نویسندگان

  • Olga Szaluś-Jordanow
  • Michał Czopowicz
  • Lucjan Witkowski
  • Marcin Mickiewicz
  • Tadeusz Frymus
  • Iwona Markowska-Daniel
  • Emilia Bagnicka
  • Jarosław Kaba
چکیده

OBJECTIVES To determine references intervals for echocardiographic measurements in adult dairy goats. ANIMALS 125 clinically healthy, adult dairy goats aged 2-9 years, belonging to two breeds-Polish Fawn Improved (PFI, n = 64, weight range from 46 to 73, median of 58.5kg) and Polish White Improved (PWI, n = 61, weight range from 48 to 80 kg, median of 67.9kg), closely related to French Alpine and Saanen, respectively. METHODS Non-invasive transthoracic echocardiography examination was performed in unsedated goats in a standing position. Two-dimensional, M-mode and pulsed wave Doppler measurements were obtained. A non-parametric method was applied for determination of reference intervals. Measurements for the two breeds were compared using an analysis of covariance to control for their body weight. Repeatability was assessed using a between-day coefficient of variation and a coefficient of repeatability. RESULTS Following reference intervals were determined: aortic diameter in diastole 2.2-3.3, left atrial diameter in systole 2.5-4.3cm cm, the ratio of the left atrial diameter to the aortic diameter 0.96-1.5, right ventricular internal diameter in diastole 0.4-1.7cm, left ventricular internal diameter in systole and diastole 1.8-3.2 and 3.2-5.6 cm, respectively, inter-ventricular septum thickness in systole and diastole 0.7-1.5 and 0.5-1.1cm, respectively, left ventricular posterior-wall in systole and diastole 0.8-1.6 and 0.5-1.2cm, respectively, E-point to septal separation 0.3-0.8cm, left ventricular fractional shortening 28-54%, left ventricular ejection fraction 55-86%, maximum Left and Right Ventricular Outflow Tract velocity 80-140 cm/s and 70-130 cm/s, respectively Left and Right Ventricular Outflow Tract pressure gradient 2.5-8.9mmHg and 1.9-6.5mmHg, respectively. Most of the differences between the two breeds could be attributed to different body weight. CONCLUSIONS The study provides echocardiographic reference intervals determined on the highest sample of apparently healthy goats so far enrolled.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

Repeatability, variability and reference values of pulsed wave Doppler echocardiographic measurements in healthy Saanen goats

BACKGROUND Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats....

متن کامل

M-mode echocardiographic reference values in Pantja goats

AIM The aim of this study was to establish M-mode echocardiographic reference values in Pantja goats and to study the effect of gender and body weight (BW) on these parameters. MATERIALS AND METHODS A total of 18, clinically healthy, adult Pantja goats of either sex, aged 2-4 years and weighing 10-44 kg were included in the study. Echocardiographic examination was performed in the standing un...

متن کامل

Reference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs

Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...

متن کامل

Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017