Influence of Temperature Gradients on Tunnel Junction Thermometry below 1 K : Cooling and Electron - Phonon Coupling

نویسندگان

  • J. T. Karvonen
  • L. J. Taskinen
  • I. J. Maasilta
چکیده

We have studied thermal gradients in thin Cu and AlMn wires, both experimentally and theoretically. In the experiments, the wires were Joule heated non-uniformly at sub-Kelvin temperatures, and the resulting temperature gradients were measured using normal metal-insulator-superconducting tunnel junctions. The data clearly shows that even in reasonably well conducting thin wires with a short (∼ 10 µm) non-heated portion, significant temperature differences can form. In most cases, the measurements agree well with a model which includes electron-phonon interaction and electronic thermal conductivity by the Wiedemann-Franz law.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metallic Coulomb blockade thermometry down to 10 mK and below.

We present an improved nuclear refrigerator reaching 0.3 mK, aimed at microkelvin nanoelectronic experiments, and use it to investigate metallic Coulomb blockade thermometers (CBTs) with various resistances R. The high-R devices cool to slightly lower T, consistent with better isolation from the noise environment, and exhibit electron-phonon cooling [proportional] T(5) and a residual heat-leak ...

متن کامل

Resonant heating and substrate-mediated cooling of a single C60 molecule in a tunnel junction

We study the influence of different metallic substrates on the electron induced heating and heat dissipation of single C60 molecules in the junction of a low temperature scanning tunneling microscope. The electron current passing through the molecule produces a large amount of heat due to electron-phonon coupling, eventually leading to thermal decomposition of the fullerene cage. The power for ...

متن کامل

Nanoelectronic primary thermometry below 4 mK

Cooling nanoelectronic structures to millikelvin temperatures presents extreme challenges in maintaining thermal contact between the electrons in the device and an external cold bath. It is typically found that when nanoscale devices are cooled to ∼ 10 mK the electrons are significantly overheated. Here we report the cooling of electrons in nanoelectronic Coulomb blockade thermometers below 4 m...

متن کامل

Inherent thermometry in a hybrid superconducting tunnel junction

We discuss inherent thermometry in a Superconductor Normal metal Superconductor tunnel junction. In this configuration, the energy selectivity of singleparticle tunneling can provide a significant electron cooling, depending on the bias voltage. The usual approach for measuring the electron temperature consists in using an additional pair of superconducting tunnel junctions as probes. In this p...

متن کامل

Direct measurement of the electron - phonon relaxation rate in thin copper films

We have used normal metal-insulator-superconductor (NIS) tunnel junction pairs, known as SINIS structures , for ultrasensitive thermometry at sub-Kelvin temperatures. With the help of these thermometers, we have developed an ac-technique to measure the electron-phonon (e-p) scattering rate directly, without any other material or geometry dependent parameters, based on overheating the electron g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006