Geometric changes after tricuspid annuloplasty and predictors of residual tricuspid regurgitation: a real-time three-dimensional echocardiography study.

نویسندگان

  • Sun-Yang Min
  • Jong-Min Song
  • Jeong-Hoon Kim
  • Min-Kyong Jang
  • Yun-Jeong Kim
  • Haeguen Song
  • Dae-Hee Kim
  • Jae Won Lee
  • Duk-Hyun Kang
  • Jae-Kwan Song
چکیده

AIMS We sought to demonstrate geometric changes in the tricuspid valve (TV) apparatus after tricuspid annuloplasty (TAP) and to identify predictors of residual tricuspid regurgitation (TR) in patients with functional TR using real-time three-dimensional echocardiography (RT3DE). METHODS AND RESULTS RT3DE and two-dimensional colour Doppler echocardiography were performed in 59 consecutive patients before and 4.7 ± 2.1 days after TAP. The tenting angles of the three leaflets were significantly increased, whereas tenting volume, annulus diameters, and septal-lateral right ventricular inlet dimension decreased after TAP. By multiple stepwise linear regression analysis, tenting volume (P < 0.001) and antero-posterior annulus diameter (P = 0.043) before TAP were major predictors of residual TR assessed using distal jet area. When TR severity was quantified by vena contracta width, tenting volume (P < 0.001) before TAP was the only independent predictor. Pre-TAP tenting volume ≥1.68 mL (sensitivity of 86%, specificity of 73%), and ≥2.30 mL (sensitivity of 100%, specificity of 84%) were the best cut-off values predicting severe residual TR quantified using distal jet area and vena contracta width, respectively. After TAP, tenting volume and pulmonary artery systolic pressure were major determinants of residual TR. CONCLUSION Tenting angles of all three leaflets increase, whereas annulus diameters decrease, after TAP. Pre-TAP tenting volume and antero-posterior annulus diameter measured using RT3DE are independent predictors of residual TR severity, and measurement of these parameters may help to identify patients at high risk for severe residual TR, for whom TV replacement should possibly be initially considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial detachment of tricuspid valve annuloplasty ring detected by three-dimensional transesophageal echocardiography

A 45-year-old female patient was admitted to our hospital with shortness of breath and swelling in the leg. Ten months prior to the admission she had undergone mitral valve replacement (31 St. Jude bioprosthesis) and tricuspid valve annuloplasty (33 Medtronic ring) because of carcinoid heart disease. All infective parameters were within the normal limits and no fever was detected. A two-dimensi...

متن کامل

Tricuspid valve tethering predicts residual tricuspid regurgitation after tricuspid annuloplasty.

BACKGROUND Tricuspid valve (TV) annuloplasty is recommended for functional tricuspid regurgitation (TR), which is caused by TV annulus dilatation and tethering of the leaflets. However, the impact of TV deformations on the outcome of TV annuloplasty remains unknown. The goal of this study was to investigate the relationship between preoperative TV deformation and residual TR after TV annuloplas...

متن کامل

Determinants of recurrent or residual functional tricuspid regurgitation after tricuspid annuloplasty.

BACKGROUND The durability of tricuspid valve (TV) repair by annuloplasty is limited. Identification of mechanisms of recurrent or residual tricuspid regurgitation (TR) after annuloplasty is necessary to improve results of TV repair. The purpose of this study was to investigate echocardiographic determinants of mid-term outcome after TV annuloplasty. METHODS AND RESULTS This study consisted of...

متن کامل

eComment. Adjustable tricuspid annuloplasty for functional tricuspid regurgitation.

Functional tricuspid regurgitation (FTR) is a neglected and underestimated pathology. It occurs mostly from annular dilatation and right ventricular enlargement, which is frequent secondary to left-sided heart failure from myocardial or valvular causes, right ventricular volume and pressure overload, and dilatation of the cardiac chambers. Moderate-to-severe FTR should be corrected to improve s...

متن کامل

Bioptome injury to the tricuspid valve in a cardiac allograft recipient visualized by three-dimensional echocardiography.

1999;88:1205–12. 7. Troianos CA, Konstadt S. Evaluation of mitral regurgitation. Semin Cardiothorac Vasc Anesth 2006;10:67–71. 8. Cook RC, Nifong LW, Lashley GG, Duncan RA, Campbell JA, Law YB et al. Echocardiographic measurements alone do not provide accurate non-invasive selection of annuloplasty band size for robotic mitral valve repair. J Heart Valve Dis 2006;15:524–7. 9. Ender J, Koncar-Ze...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 31 23  شماره 

صفحات  -

تاریخ انتشار 2010