A pilot study of pulse contour cardiac output monitoring in patients with septic shock.

نویسندگان

  • L Wan
  • T Naka
  • S Uchino
  • R Bellomo
چکیده

OBJECTIVE To assess the relationship between PiCCO-derived signals and conventional measures of pre-load and gas exchange in patients with septic shock. METHODS Prospective observational study of 23 patients with septic shock. Scheduled collection of clinical, conventional haemodynamic and PiCCO derived variables. Statistical analysis of correlations. RESULTS Patients had a mean SAPS II score of 53.5 +/- 14.5 with 78.3% on mechanical ventilation at PiCCO insertion. PiCCO monitoring lasted a mean of 4.3 +/- 2.9 days. SAPS II predicted 28-day mortality was 54.2%, while actual mortality was 39.1%. At PiCCO insertion, there was an inverse correlation between cardiac (CI) and extravascular lung water index (EVLWI) (r = -0.442; p < 0.05). During treatment, the most significant correlation was between the PiCCO-derived global end-diastolic volume index (GEDVI) and PaO(2)/F(I)O(2) ratio (r = 0.386; p < 0.01). There was also a correlation between changes in GEDVI and changes in CI (r = 0.329; p < 0.01). Increases in EVLWI correlated with decreases in PaO(2)/F(I)O(2) ratio( )(r = -0.332; p < 0.01). CONCLUSIONS PiCCO-derived pre-load and extravascular lung water signals show logical associations with conventional indirect indicators of haemodynamic and fluid status suggesting physiological and clinical relevance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis.

BACKGROUND Recently, continuous monitoring of cardiac output (CO) based on pulse contour analysis (Vigileo) has been introduced into practice. In this clinical study, we evaluated the accuracy of this system by comparing it with the transpulmonary thermodilution technique (TPID) in septic patients. METHODS We studied 24 mechanically ventilated patients with septic shock (16 male, 8 female, ag...

متن کامل

Sequential Organ Failure Assessment predicts outcomes of pulse indicator contour continuous cardiac output-directed goal therapy

According to the new sepsis definitions, septic shock is defined as a subset of sepsis in which the underlying circulatory and cellular/metabolic abnormalities are profound enough to substantially increase mortality. We evaluated the predictive efficacy of the Sequential Organ Failure Assessment (SOFA) score in critically ill patients with septic shock undergoing pulse indicator contour continu...

متن کامل

Use of the PiCCO system in critically ill patients with septic shock and acute respiratory distress syndrome: a study protocol for a randomized controlled trial

BACKGROUND Hemodynamic monitoring is very important in critically ill patients with shock or acute respiratory distress syndrome(ARDS). The PiCCO (Pulse index Contour Continuous Cardiac Output, Pulsion Medical Systems, Germany) system has been developed and used in critical care settings for several years. However, its impact on clinical outcomes remains unknown. METHODS/DESIGN The study is a...

متن کامل

Extravascular lung water index as an indicator of lung injury in septic patients

Introduction. Transpulmonary thermodilution using PiCCO (Pulse-induced Contour Cardiac Output) is a standard minimally invasive method used for haemodynamic monitoring. Objectives. The goal of this paper is to examine the correlation and dynamics of the ExtraVascular Lung Water Index (EVLWI) as an indicator of acute lung injury in septic patients who underwent major abdominal surgery. Two group...

متن کامل

An advertising card for peruvian syrup.

views of evaluations of diagnostic and screening tests. BMJ 2001; 323:157– 62 27. Harbord RM, Deeks JJ, Egger M, Whiting P, Sterne JA: A unification of models for meta-analysis of diagnostic accuracy studies. Biostatistics 2007; 8:239 –51 28. Monnet X, Anguel N, Naudin B, Jabot J, Richard C, Teboul JL: Arterial pressure-based cardiac output in septic patients: Different accuracy of pulse contou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care and resuscitation : journal of the Australasian Academy of Critical Care Medicine

دوره 7 3  شماره 

صفحات  -

تاریخ انتشار 2005