Correlation between central corneal thickness and intraocular pressure in various age groups.

نویسندگان

  • Ivan Marjanović
  • Djordje Kontić
  • Paraskeva Hentova-Senćanić
  • Vujica Marković
  • Marija Bozić
چکیده

INTRODUCTION The Pascal Dynamic Contour Tonometer (DCT) is an ophthalmic investigational device which directly calculates the dynamic pulsatile fluctuations in intraocular pressure (IOP) using a piezoelectric pressure sensor embedded in the devices tip. OBJECTIVE The aim of this study was to compare IOP results obtained with Goldmann applanation tonometer (GAT), and their correlation with central corneal thickness (CCT) in patients of various age groups. METHODS We studied 37 patients (17 male and 20 female), divided into three age groups: younger than 40 years; 40-60 years old, and older than 60 years. In the first and second group there were patients rarely and in the third mostly diagnosed and medicamentously compensated glaucoma. In topical anaesthesia, first we measured CCT, with ultrasound pachimeter, then IOP with DCT and GAT. RESULTS Statistically significant difference between measurements of IOP with the DCT and GAT appeared in all groups: I mean diff. -1.71 +/- 1.27 mm; p < 0.0001; II mean diff. -1.19 +/- 1.06 mm; p < 0.0001; III mean diff. -1.69 +/- 1.67 mm; p < 0.0001. CCT was in indirect correlation with the values of IOP measured both with the DCT and GAT in the first and third, while it was in the direct correlation with these values in the second group. CONCLUSION CCT had no influence on IOP measurements both with the DCT and GAT in none of the groups. The DCT cannot replace GAT, but it is a reliable device for the measurement of IOP particularly in corneal deformations (keratoconus, after corneal refractive surgery, corneal scars, etc.).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن

To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...

متن کامل

Correlation between central corneal thickness and intraocular pressure peak and fluctuation during the water drinking test in glaucoma patients

OBJECTIVE To investigate the correlation between central corneal thickness and outflow facility assessed by intraocular pressure peak and fluctuation during the water drinking test. METHODS Fifty-five newly diagnosed primary open-angle glaucoma patients submitted to central corneal thickness measurements and water drinking test were enrolled in this retrospective study.;. Patients were divide...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Corneal Endothelial Characteristics, Central Corneal Thickness, and Intraocular Pressure in a Population of Chinese Age-Related Cataract Patients

PURPOSE To describe corneal endothelial characteristics, central corneal thickness, and intraocular pressure in a population of Chinese age-related cataract patients and to determine the effects of age, gender, hypertension, and body mass index (BMI). METHODS 1551 eyes were examined preoperatively. The parameters measured were endothelial cell density (CD), average cell area (CA), coefficient...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Srpski arhiv za celokupno lekarstvo

دوره 138 5-6  شماره 

صفحات  -

تاریخ انتشار 2010