Determination of vaginal pH by pH indicator strip and by pH micro electrode.

نویسندگان

  • T Heinze
  • S Riedewald
  • E Saling
چکیده

Vaginal pH measurement is a screening method of vaginal infection in pregnancy. We tested two different methods of pH determination. In freshly taken vaginal fluid measurements were carried out with special pH indicator strips and pH micro glass electrode. About 100 microliters of vaginal fluid is enough when pH indicator strips are used, and 200 microliters when the micro electrode is used. The accuracy of the pH measurement by indicator strip is about 0.1-0.2 pH and by electrode 0.01 pH. Both methods show a good correlation between pH 4.0 to 7.0 (p = 0.0000). Until a pH of up to 4.3 we recommend the pH determination by indicator strips. In all cases with the possible risk of infection (pH values greater than 4.3) the micro electrode should be used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the RightLevelpHTM Detector for Monitoring Gastric pH Running Title: Gastric pH Monitoring

Background: The RightLevelpHTM indicator is a new device designed to measure pH of gastric aspirate obtained via nasogastric tube while minimizing exposure of the operator. Study Objectives: In vivo and in vitro validation of the RightLevelpHTM indicator. Methods: Patients (23) undergoing general anesthesia had placement of a nasogastric tube and gastric pH electrode catheter following endotrac...

متن کامل

Validation of the RightSpotTM device for determination of gastric pH during nasogastric tube placement

Background: The RightSpotpHTM indicator is a new device designed to facilitate pH-based confirmation of nasogastric tube placement while minimizing exposure of the operator to nasogastric contents. Study objectives: In vivo and in vitro validation of the RightSpotpHTM indicator. Findings: Patients (23) undergoing general anesthesia had placement of a nasogastric tube and gastric pH electrode ca...

متن کامل

Validation of the RightSpot™ device for determination of gastric pH during nasogastric tube placement

BACKGROUND The RightSpotpH™ indicator is a new device designed to facilitate pH-based confirmation of nasogastric tube placement while minimizing exposure of the operator to nasogastric contents. STUDY OBJECTIVES In vivo and in vitro validation of the RightSpotpH™ indicator. FINDINGS Patients (23) undergoing general anesthesia had placement of a nasogastric tube and gastric pH electrode cat...

متن کامل

Determination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore

In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of perinatal medicine

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 1989