Computational analysis of microfluidic immunomagnetic rare cell separation from a particulate blood flow.

نویسندگان

  • Kazunori Hoshino
  • Peng Chen
  • Yu-Yen Huang
  • Xiaojing Zhang
چکیده

We describe a computational analysis method to evaluate the efficacy of immunomagnetic rare cell separation from non-Newtonian particulate blood flow. The core procedure proposed here is calculation of local viscosity distributions induced by red blood cell (RBC) sedimentation. Numerical calculation methods have previously been introduced to simulate particulate behavior of individual RBCs. However, due to the limitation of the computational power, those studies are typically capable of calculating only a very small number (less than 100) of RBCs and are not suitable to analyze many practical separation methods for rare cells such as circulating tumor cells (CTCs). We introduce a sedimentation and viscosity model based on our experimental measurements. The computational field is divided into small unit control volumes, where the local viscosity distribution is dynamically calculated based on the experimentally found sedimentation model. For analysis of rare cell separation, the local viscosity distribution is calculated as a function of the volume RBC rate. The direction of gravity has an important role in such a sedimentation-involved cell separation system. We evaluated the separation efficacy with multiple design parameters including the channel design, channel operational orientations (inverted and upright), and flow rates. The results showed excellent agreement with real experiments to demonstrate the effectiveness of our computational analytical method. We demonstrated higher capture efficiency with the inverted microchannel configuration.We conclude that proper direction of blood sedimentation significantly enhances separation efficiency in microfluidic devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunomagnetic T cell capture from blood for PCR analysis using microfluidic systems.

A one-step immunomagnetic separation technique was performed on a microfluidic platform for the isolation of specific cells from blood samples. The cell isolation and purification studies targeted T cells, as a model for low abundance cells (about 1:10,000 cells), with more dilute cells as the ultimate goal. T cells were successfully separated on-chip from human blood and from reconstituted blo...

متن کامل

Highly Selective Capture and Transport of Rare Cells in Microfluidic Channels

Collection of rare target cells in clinical samples such as disseminated tumor cells in peripheral blood, poses difficult challenges to currently available cell separation methods. A novel, two stage microfluidic system enabling highly efficient and specific concentration of rare target cells has been developed. It uses immunomagnetic separation in fluidic channels to isolate target cells to na...

متن کامل

Immunomagnetic nanoscreening of circulating tumor cells with a motion controlled microfluidic system.

Combining the power of immunomagnetic assay and microfluidic microchip operations, we successfully detected rare CTCs from clinical blood samples. The microfluidic system is operated in a flip-flop mode, where a computer-controlled rotational holder with an array of microfluidic chips inverts the microchannels. We have demonstrated both theoretically and experimentally that the direction of red...

متن کامل

Enrichment of rare cancer cells through depletion of normal cells using density and flow-through, immunomagnetic cell separation.

OBJECTIVE To develop a reliable technique to enrich for rare cells in blood suspensions using only negative selection steps including a flow-through immunomagnetic cell separations system and by optimizing variables normally encountered during such enrichment processes. METHODS A human breast cancer cell line was cultivated and spiked at a ratio of 1 cancer cell to 10(5) total leukocytes in b...

متن کامل

Microfluidic assay of circulating endothelial cells in coronary artery disease patients with angina pectoris

BACKGROUND Circulating endothelial cells (CECs) are widely reported as a promising biomarker of endothelial damage/dysfunction in coronary artery disease (CAD). The two popular methods of CEC quantification include the use of immunomagnetic beads separation (IB) and flow cytometry analysis (FC); however, they suffer from two main shortcomings that affect their diagnostic and prognostic response...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 84 10  شماره 

صفحات  -

تاریخ انتشار 2012