Free breathing real-time cardiac cine imaging with improved spatial resolution at 3 T.

نویسندگان

  • Felix Schwab
  • Florian Schwarz
  • Olaf Dietrich
  • Titus Lanz
  • Frank Resmer
  • Tobias Wichmann
  • Bernd J Wintersperger
  • Fabian Bamberg
  • Konstantin Nikolaou
  • Maximilian Reiser
  • Daniel Theisen
چکیده

OBJECTIVES The aim of this study was to evaluate free-breathing single-shot real-time cine imaging for functional cardiac imaging at 3 T with increased spatial resolution. Special emphasis of this study was placed on the influence of parallel imaging techniques. MATERIALS AND METHODS Gradient echo phantom images were acquired with GRAPPA and modified SENSE reconstruction using both integrated and separate reference scans as well as TGRAPPA and TSENSE. In vivo measurements were performed for GRAPPA reconstruction with an integrated and a separate reference scan, as well as TGRAPPA using balanced steady-state free precession protocols. Three clinical protocols, rtLRInt (Tres = 51.3 milliseconds; voxel, 2.5 × 5.0 × 10 mm³), rtMRSep (Tres = 48.8 milliseconds; voxel, 1.9 × 3.1 × 10 mm³), and rtHRSep (Tres = 48.3 milliseconds; voxel, 1.6 × 2.6 × 10 mm), were investigated on 20 volunteers using GRAPPA reconstruction with internal as well as separate reference scans. End-diastolic volume, end-systolic volume, ejection fraction, peak ejection rate, peak filling rate, and myocardial mass were evaluated for the left ventricle and compared with an electrocardiogram-triggered segmented readout cine protocol used as standard of reference. All studies were performed at 3 T. RESULTS Phantom and in vivo data demonstrate that the combination of GRAPPA reconstruction with a separate reference scan provides an optimal compromise of image quality as well as spatial and temporal resolution. Functional values (P values) for the standard of reference, rtLRInt, rtMRSep, and rtHRSep end-diastolic volume were 141 ± 24 mL, 138 ± 21 mL, 138 ± 19 mL, and 128 ± 33 mL, respectively (P = 0.7, 0.7, 0.4); end-systolic volume, 55 ± 15 mL, 61 ± 14 mL, 58 ± 12 mL, and 55 ± 20 mL, respectively (P = 0.23, 0.43, 0.62); ejection fraction, 61% ± 5%, 57% ± 5%, 58% ± 4%, and 56% ± 8%, respectively (P = 0.01, 0.11, 0.06); peak ejection rate, 481 ± 73 mL/s, 425 ± 62 mL/s, 434 ± 67 mL/s, and 381 ± 86 mL/s, respectively (P = 0.03, 0.04, 0.01); peak filling rate, 555 ± 80 mL/s, 480 ± 70 mL/s, 500 ± 70 mL/s, and 438 ± 108 mL/s, respectively (P= 0.007, 0.05, 0.004); and myocardial mass, 137 ± 26 g, 141 ± 25 g, 141 ± 23 g, and 130 ± 31 g, respectively (P = 0.62, 0.54, 0.99). CONCLUSIONS Using a separate reference scan and high acceleration factors up to R = 6, single-shot real-time cardiac imaging offers adequate temporal and spatial resolution for accurate assessment of global left ventricular function in free breathing with short examination times.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting.

Cine MRI is used for assessing cardiac function and flow and is typically based on a breath-held, segmented data acquisition. Breath holding is particularly difficult for patients with congestive heart failure or in pediatric cases. Real-time imaging may be used without breath holding or ECG triggering. However, despite the use of rapid imaging sequences and accelerated parallel imaging, real-t...

متن کامل

Self-Gated Free-Breathing 3D Coronary CINE Imaging with Simultaneous Water and Fat Visualization

The aim of this study was to develop a novel technique for acquiring 3-dimensional (3D) coronary CINE magnetic resonance images with both water and fat visualization during free breathing and without external respiratory or cardiac gating. The implemented multi-echo hybrid 3D radial balanced Steady-State Free Precession (SSFP) sequence has an efficient data acquisition and is robust against mot...

متن کامل

Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging.

Real-time imaging may be clinically important in patients with congestive heart failure, arrhythmias, or in pediatric cases. However, real-time imaging typically has compromised spatial and temporal resolution compared with gated, segmented studies. To combine the best features of both types of imaging, a new method is proposed that uses parallel imaging to improve temporal resolution of real-t...

متن کامل

High spatial and temporal resolution retrospective cine cardiovascular magnetic resonance from shortened free breathing real-time acquisitions

BACKGROUND Cine cardiovascular magnetic resonance (CMR) is challenging in patients who cannot perform repeated breath holds. Real-time, free-breathing acquisition is an alternative, but image quality is typically inferior. There is a clinical need for techniques that achieve similar image quality to the segmented cine using a free breathing acquisition. Previously, high quality retrospectively ...

متن کامل

Cardiac functional analysis by free-breath real-time cine CMR with a spatiotemporal filtering method, TSENSE: comparison with breath-hold cine CMR.

The aim of this study was to assess the accuracy of cardiac functional values obtained from free-breathing real-time cine CMR with the temporal sensitivity encoding (TSENSE) technique by comparing them with values obtained from conventional cine CMR. For the real-time cine CMR, two protocols were employed, one with good temporal resolution and one with good spatial resolution. The functional va...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 2013