Validation of "transit renography" for the determination of the intrarenal distribution of plasma flow: comparison with the microsphere method in the anaesthetized rabbit and pig.

نویسندگان

  • S P Wilkinson
  • M Bernardi
  • P C Pearce
  • K E Britton
  • N J Brown
  • L Poston
  • M Clarke
  • R Jenner
  • R Williams
چکیده

1. The spectrum of transit times of sodium o-iodohippurate (Hippuran) through the kidney can be derived from an 131I- (or 123I-) labelled Hippuran renogram by deconvolution. In the rabbit and pig, as has previously been shown in man, the frequency distribution curve for the transit times was bimodal. Since the transit time is likely to be proportional to the nephron length, the area of the first mode is likely to represent plasma flow to the shorter outer cortical nephrons whereas the delayed mode represents flow to the long juxtamedullary nephrons. 2. This interpretation was tested by simultaneously comparing renography with the microsphere method of measuring intrarenal plasma flow distribution in 12 rabbits and two pigs with a variety of anaesthetics. A close agreement was found between both methods for the percentage of plasma flow distributed to the outer cortical nephrons, thus supporting the use of "transit renography" to determine the intrarenal distribution of plasma flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of a HPLC Method for Determination of Pefloxacin in Tablet and Human Plasma

Objective(s) Developing and validating a simple, efficient, reproducible and economic reversed phase high performance liquid chromatographic (RP-HPLC) method for the quantitative determination of pefloxacin in bulk material, tablets and in human plasma. Materials and Methods A shim-pack CLC-ODS column and a mobile phase constituting acetonitrile: 0.025 M phosphoric acid solution (13:87 v/v, ...

متن کامل

Intrarenal distribution of plasma flow in cirrhosis as measured by transit renography: relationship with plasma renin activity, and sodium and water excretion.

1. The intrarenal distribution of plasma flow was determined with a technique based on the analysis of the transit time of sodium o-[131I]- iodohippurate through the kidney in 43 patients with cirrhosis with near-normal total renal perfusion. 2. Twenty-five of the patients had an abnormal pattern of transit times, suggesting a redistribution of plasma flow from outer cortical to juxtamedullary ...

متن کامل

Development and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection

A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...

متن کامل

Development and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection

A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...

متن کامل

Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase

Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science and molecular medicine

دوره 55 3  شماره 

صفحات  -

تاریخ انتشار 1978