چکیده

Dual-energy CT (DECT) is accomplished by near simultaneous imaging at two energy levels, typically 80 kV and 140 kV, using scanners that either employ rapid kV switching or have two orthogonal sets of X-ray tunes and detectors mounted in the gantry. Attenuation properties differ at the two energy levels, which allow the DECT to differentiate and quantify certain substances such as water, calcium, and iodine (from CT contrast medium). The low energy settings (lower monoenergetic level) of the DECT can provide excellent contrast enhancement while the higher energy setting can help obtain high signal-to-noise ratios if the penetration of X-rays is not sufficient at low energy levels.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study

  In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...

متن کامل

Dual-energy CT imaging of thoracic malignancies

Computed tomography (CT) plays a pivotal role in the detection, characterization, and staging of lung cancer and other thoracic malignancies. Since the introduction of clinically viable dual-energy CT techniques, substantial evidence has accumulated on the use of this modality for imaging chest malignancies. This article describes the principles of dual-energy CT along with suitable image acqui...

متن کامل

Comparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data

Introduction:  The  advent  of  dual-modality  PET/CT  scanners  has  revolutionized  clinical  oncology  by  improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of  CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates  a noise-free  attenuation  map  (6map).  CTAC  methods  include  scaling,  s...

متن کامل

Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography

Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...

متن کامل

Comparing the Diagnostic Power of Chest CT Scan and RT-PCR in Diagnosis of COVID-19

Background and purpose: Proper diagnosis of patients with COVID-19 is one of the challenges in medical centers. RT-PCR is the standard and reference test in diagnosis of patients with COVID-19. This study aimed at accelerating the correct diagnosis of COVID-19 and the diagnostic power of chest CT scan and RT-PCR. Materials and methods: This study was performed in 569 patients with COVID-19 adm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014