Dual-energy CT in the Chest
ثبت نشده
چکیده
Dual-energy CT (DECT) is accomplished by near simultaneous imaging at two energy levels, typically 80 kV and 140 kV, using scanners that either employ rapid kV switching or have two orthogonal sets of X-ray tunes and detectors mounted in the gantry. Attenuation properties differ at the two energy levels, which allow the DECT to differentiate and quantify certain substances such as water, calcium, and iodine (from CT contrast medium). The low energy settings (lower monoenergetic level) of the DECT can provide excellent contrast enhancement while the higher energy setting can help obtain high signal-to-noise ratios if the penetration of X-rays is not sufficient at low energy levels.
منابع مشابه
A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study
In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...
متن کاملDual-energy CT imaging of thoracic malignancies
Computed tomography (CT) plays a pivotal role in the detection, characterization, and staging of lung cancer and other thoracic malignancies. Since the introduction of clinically viable dual-energy CT techniques, substantial evidence has accumulated on the use of this modality for imaging chest malignancies. This article describes the principles of dual-energy CT along with suitable image acqui...
متن کاملComparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data
Introduction: The advent of dual-modality PET/CT scanners has revolutionized clinical oncology by improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates a noise-free attenuation map (6map). CTAC methods include scaling, s...
متن کاملClinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...
متن کاملComparing the Diagnostic Power of Chest CT Scan and RT-PCR in Diagnosis of COVID-19
Background and purpose: Proper diagnosis of patients with COVID-19 is one of the challenges in medical centers. RT-PCR is the standard and reference test in diagnosis of patients with COVID-19. This study aimed at accelerating the correct diagnosis of COVID-19 and the diagnostic power of chest CT scan and RT-PCR. Materials and methods: This study was performed in 569 patients with COVID-19 adm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014