Helical SPECT Using Axially Truncated Data
نویسندگان
چکیده
In this study, use of a helical orbit in performing a long object SPECT scan with parallel, cone, fan, rotated fan, varying focal-length cone, divergent, and astigmatic collimators is proposed. Sufficient-data scanning helical orbits for these collimation geometries are developed. Both singledetector system and multi-detector system are considered. In order to verify our orbit design requirement, the iterative MLEM algorithm is used to reconstruct images of a long Defrise phantom. The phantom height is five times the height of the detectors. Computer simulations are performed and exact reconstructions are obtained. The proposed sufficient helical orbit pitch will facilitate performing whole body SPECT and PET scans that demand an exact reconstruction.
منابع مشابه
SPECT region of interest reconstruction with truncated transmission and emission data.
PURPOSE The aim of this article is to propose an exact SPECT region of interest (ROI) reconstruction method using truncated transmission and truncated emission data. METHODS Recently, the authors published two articles in Physics in Medicine and Biology with two results in SPECT ROI emission image reconstruction. The first result states that if the transmission data are truncated but the emis...
متن کاملA Reconstruction Algorithm for Helical Cone-Beam SPECT
Cone-beam SPECT provides improved sensitivity for imaging small organs like the brain and heart. However, current cone-beam tomography with the focal point traversing a planar orbit does not acquire sufficient data to give an accurate reconstruction. In this paper, we employ a data-acquisition method which obtains complete data for cone-beam SPECT by simultaneously rotating the gamma camera and...
متن کاملInterior SPECT- Exact and Stable ROI Reconstruction from Uniformly Attenuated Local Projections.
Single photon emission computed tomography (SPECT) is an important biomedical imaging modality. However, since gamma cameras are expensive and bulky, truncated projection data are either preferred or unavoidable. Inspired by the recent results on interior tomography in the x-ray CT field, here we present the interior SPECT approach for exact and stable reconstruction of a region of interest (RO...
متن کاملExact emission SPECT reconstruction with truncated transmission data.
UNLABELLED It is common, even with new SPECT/CT systems, that the transmission data are truncated. This paper develops a method that obtains exact attenuation correction with truncated transmission data. The emission object (e.g., the heart) is assumed to have a finite, convex support, whose emission projections are not truncated. The transmission measurements over the support are available, bu...
متن کامل3D Image Reconstruction from Truncated Helical Cone Beam Projection Data - A Linear Prediction Approach
With the introduction of 2D flat-panel X-ray detectors, 3D image reconstruction using helical cone-beam tomography is fast replacing the conventional 2D reconstruction techniques. In 3D image reconstruction, the source orbit or scanning geometry should satisfy the data sufficiency or completeness condition for exact reconstruction. The helical scan geometry satisfies this condition and hence ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004