Centration axis in refractive surgery
نویسندگان
چکیده
The human eye is an asymmetric optical system and the real cornea is not a rotationally symmetrical volume. Each optical element in the eye has its own optical and neural axes. Defining the optimum center for laser ablation is difficult with many available approaches. We explain the various centration approaches (based on these reference axes) in refractive surgery and review their clinical outcomes. The line-of-sight (LOS) (the line joining the entrance pupil center with the fixation point) is often the recommended reference axis for representing wavefront aberrations of the whole eye (derived from the definition of chief ray in geometrical optics); however pupil centration can be unstable and change with the pupil size. The corneal vertex (CV) represents a stable preferable morphologic reference which is the best approximate for alignment to the visual axis. However, the corneal light reflex can be considered as non-constant, but dependent on the direction of gaze of the eye with respect to the light source. A compromise between the pupil and CV centered ablations is seen in the form of an asymmetric offset where the manifest refraction is referenced to the CV while the higher order aberrations are referenced to the pupil center. There is a need for a flexible choice of centration in excimer laser systems to design customized and non-customized treatments optimally.
منابع مشابه
Treatment-induced shifts of ocular reference axes used for measurement centration.
PURPOSE To determine the shifts of the main corneal reference points in dependence of the chosen centration axis for the treatment. SETTING Federal Institute of Technology Zurich, Institute of Biomedical Engineering, Zurich, Switzerland. METHODS Computer simulations were performed on several variants of the Gullstrand-Emsley schematic eye, which was modified by an off-axis fovea. Refractive...
متن کاملObjective analysis of toric intraocular lens rotation and centration.
PURPOSE To assess the repeatability of an objective image-analysis technique to determine intraocular lens (IOL) rotation and centration. SETTING Six European ophthalmology clinics. METHODS Eyes with an Akreos AO aspheric IOL with orientation marks were imaged. A masked observer rated image quality. The axis of rotation was determined from a line bisecting the IOL orientation marks. This wa...
متن کاملDigital pupillometry and centroid shift changes after cataract surgery.
PURPOSE To compare postoperative changes in apparent photopic and mesopic pupil size and centration in relation to cornea reflection landmarks after cataract surgery. SETTING LaserVision.gr Clinical and Research Eye Institute, Athens, Greece. DESIGN Prospective consecutive case study. METHODS Pupils were imaged for pupil size and corneal vertex location before and 1-month after cataract s...
متن کاملAcuTarget measurements: repeatability and comparison to OPD-Scan III.
PURPOSE To evaluate repeatability of the AcuTarget (SensoMotoric Instruments, Teltow, Germany) measurements and compare them to those obtained with the OPD-Scan III (NIDEK, Inc., Fremont, CA). METHODS Measurements were taken with the AcuTarget and OPD-Scan III in 62 eyes of 31 patients. Results were compared using paired Student's t tests, Pearson correlation coefficients, and 95% limits of a...
متن کاملComparison of myopic LASIK centered on the coaxially sighted corneal light reflex or line of sight.
PURPOSE To compare refractive outcomes of myopic LASIK with centration on the coaxially sighted corneal light reflex (CSCLR) to centration on the center of the pupil (line of sight [LOS]). METHODS The NIDEK CXIII excimer laser was used to treat 268 eyes with centration on the CSCLR (CSCLR group) and 288 eyes with centration on the LOS (LOS group). For the CSCLR group, the laser ablation was d...