CMIstark: Python package for the Stark-effect calculation and symmetry classification of linear, symmetric and asymmetric top wavefunctions in dc electric fields
نویسندگان
چکیده
The Controlled Molecule Imaging group (CMI) at the Center for Free Electron Laser Science (CFEL) has developed the CMIstark software to calculate, view, and analyze the energy levels of adiabatic Stark energy curves of linear, symmetric top and asymmetric top molecules. The program exploits the symmetry of the Hamiltonian to generate fully labeled adiabatic Stark energy curves. CMIstark iswritten in Python and easily extendable,while the core numerical calculationsmakeuse of machine optimized BLAS and LAPACK routines. Calculated energies are stored in HDF5 files for convenient access and programs to extract ASCII data or to generate graphical plots are provided.
منابع مشابه
Accuracy Evaluation of Isogray TPS Dose Calculations in Symmetric and Asymmetric Fields of the Elekta Compact Linear Accelerator
Introduction: Radiation therapy is one of the most important methods of cancer treatment. Radiation therapy uses symmetric and asymmetric fields in which the radiation dose distribution is different. To calculate the dose distribution, computer treatment planning systems are used which must have acceptable calculations accuracy. The aim of this study was to investigate the accuracy of the dose ...
متن کاملCharacterization of Wedge Factors and Dose Distributions in Radiotherapy with Symmetric and Asymmetric Physical Wedged Beams of 6 MV Photon Beam
Introduction: Physical wedge by modify photon beam shape and intensity has been utilized in radiotherapy to obtain uniformly dose distribution in tumor site with reduced hot spots. Calculation of dosimetric parameters for both symmetric and asymmetric wedged fields is proved necessary during linear accelerator (Linac) commissioning. The present study aimed to achieve o...
متن کاملDosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields
Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...
متن کاملQuantification the dosimetric parameters of asymmetric physical wedged-6MV photon beam
Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the par...
متن کاملEffect of Phase Choices in Rovibrational Wavefunctions on the Labeling of K- and /-Type Doubling in Molecular Energy Levels
The change in phase factor of the wavefunction does not affect the absolute value of the matrix element, but does change the phase factor of the off-diagonal matrix element. This phase dependence causes a serious confusion in the sign of some parameters in the molecular Hamiltonian, which appear only in the off-diagonal matrix element; for example, the sign of the /-type doubling constant q of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer Physics Communications
دوره 185 شماره
صفحات -
تاریخ انتشار 2014