CMIstark: Python package for the Stark-effect calculation and symmetry classification of linear, symmetric and asymmetric top wavefunctions in dc electric fields

نویسندگان

  • Yuan-Pin Chang
  • Frank Filsinger
  • Boris G. Sartakov
  • Jochen Küpper
چکیده

The Controlled Molecule Imaging group (CMI) at the Center for Free Electron Laser Science (CFEL) has developed the CMIstark software to calculate, view, and analyze the energy levels of adiabatic Stark energy curves of linear, symmetric top and asymmetric top molecules. The program exploits the symmetry of the Hamiltonian to generate fully labeled adiabatic Stark energy curves. CMIstark iswritten in Python and easily extendable,while the core numerical calculationsmakeuse of machine optimized BLAS and LAPACK routines. Calculated energies are stored in HDF5 files for convenient access and programs to extract ASCII data or to generate graphical plots are provided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Evaluation of Isogray TPS Dose Calculations in Symmetric and Asymmetric Fields of the Elekta Compact Linear Accelerator

Introduction: Radiation therapy is one of the most important methods of cancer treatment. Radiation therapy uses symmetric and asymmetric fields in which the radiation dose distribution is different. To calculate the dose distribution, computer treatment planning systems are used which must have acceptable calculations accuracy. The aim of this study was to investigate the accuracy of the dose ...

متن کامل

Characterization of Wedge Factors and Dose Distributions in Radiotherapy with Symmetric and Asymmetric Physical Wedged Beams of 6 MV Photon Beam

Introduction: Physical wedge by modify photon beam shape and intensity has been utilized in radiotherapy to obtain uniformly dose distribution in tumor site with reduced hot spots. Calculation of dosimetric parameters for both symmetric and asymmetric wedged fields is proved necessary during linear accelerator (Linac) commissioning. The present study aimed to achieve o...

متن کامل

Dosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields

Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...

متن کامل

Quantification the dosimetric parameters of asymmetric physical wedged-6MV photon beam

Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the par...

متن کامل

Effect of Phase Choices in Rovibrational Wavefunctions on the Labeling of K- and /-Type Doubling in Molecular Energy Levels

The change in phase factor of the wavefunction does not affect the absolute value of the matrix element, but does change the phase factor of the off-diagonal matrix element. This phase dependence causes a serious confusion in the sign of some parameters in the molecular Hamiltonian, which appear only in the off-diagonal matrix element; for example, the sign of the /-type doubling constant q of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer Physics Communications

دوره 185  شماره 

صفحات  -

تاریخ انتشار 2014