Application of dose compensation in image-guided radiotherapy of prostate cancer.

نویسندگان

  • Qiuwen Wu
  • Jian Liang
  • Di Yan
چکیده

In image-guided radiation therapy (IGRT), volumetric information on patient anatomy at treatment conditions is made available with in-room imaging devices capable of cone-beam CT. Setup error and inter-fraction rigid motion can be corrected online. The planning margin can therefore be reduced significantly. However, to compensate for uncertainties including organ deformation and intra-fraction motion, offline evaluation and replanning are necessary. The purpose of this study is to investigate the use of an offline dose compensation technique to further reduce the margin safely. In IGRT, online CT scan, rigid image registration and setup correction are performed at each fraction. Later the regions of interest are registered offline between treatment and planning CTs using a finite element method to account for non-rigid organ motion. Cumulative dose distribution is calculated and compared with the prescription dose. The discrepancy, if found significant, is repaired using the dose compensation technique, in which the cumulative dose distribution is incorporated in adaptive IMRT planning for future fractions. Two compensation schedules were tested in this study: single compensation at the end of the treatment course and compensation performed weekly. One patient with one planning CT and 16 treatment CTs were used in this simulation study. Due to the aggressive smaller planning margin used, severe underdose was observed in the clinical target volume. The size and magnitude of the underdose were reduced substantially with online guidance but were still significant. Both dose compensation strategies were able to reduce the dose deficit to an acceptable level without additional planning margin. Weekly compensation is more biologically beneficial and can spread the execution error into multiple fractions. The offline dose compensation technique allows further margin reduction and can complement the online guidance by compensating for uncertainties that cannot be reduced online, thereby increasing the confidence in IGRT delivery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Health technology assessment of image-guided radiotherapy (IGRT): A systematic review of current evidence

Background: Image-guided radiotherapy used multiple imaging during the radiation therapy course to improve the precision and accuracy of health care provider's treatment. Objectives: This study aims to assess the safety, effectiveness and economic aspects of image-guided radiation therapy for decision-making about this technology in Iran. Methods: In this study, the most important med...

متن کامل

Dosimetric and Radiobiological Evaluation of Multiparametric MRI-guided Dose Painting in radiotherapy of Prostate Cancer

Introduction: Radiotherapy is one of the treatment options for locally advanced prostate cancer, however with standard radiation doses it is not always very effective. One of the strategies to improve the efficiency of radiotherapy is increasing the dose. In this study to increase tumor local control rates a new radiotherapy method, known as dose painting (DP) was investigated....

متن کامل

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...

متن کامل

Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer

Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...

متن کامل

Image-guided prostate radiotherapy: analysis of inter- fractional setup errors

Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...

متن کامل

Clinical application of image-guided radiotherapy in bladder and prostate cancer.

Advances in radiotherapy planning reduced the volumes of irradiated normal tissue and allowed safe dose escalation in prostate cancer. Image-guided radiotherapy solutions to prostate and bladder cancer offer further improvements. The initial process is understanding the causes and extent of internal organ motion, followed by development of equipment and protocols to minimise geographical miss. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 51 6  شماره 

صفحات  -

تاریخ انتشار 2006