A novel Time-resolved Fluoroimmunoassay for the quantitative detection of Antibodies against the Phospholipase A2 Receptor

نویسندگان

  • Biao Huang
  • Liang Wang
  • Yi Zhang
  • Jue Zhang
  • Qiuhua Zhang
  • Hualong Xiao
  • Bin Zhou
  • Zhuxing Sun
  • Ya-nan Cao
  • Yu Chen
  • Zhigang Hu
  • Huiming Sheng
چکیده

A highly sensitive time-resolved fluoroimmunoassay (TRFIA) was developed to quantify serum antibodies against the phospholipase A2 receptor (anti-PLA2R-IgG) for differential diagnosis of membranous nephropathy. Recombinant PLA2R (rPLA2R) was coated onto 96-well plates as a capture. A goat-anti-human IgG tracer was prepared with europium-chelate for detection. After bound/free separation by washing, the fluorescence counts of bound tracer were measured for quantifying serum anti-PLA2R-IgG concentration. A purified anti-PLA2R-IgG calibrator was first prepared for ensuring that consistent quantitative results could be obtained. The assay detection limit was 0.03 mg/L with linear measurement range of 0.03-340 mg/L. The intra- and inter-assay coefficients of variation (CVs) were 3.8% and 6.2%, respectively. The average serum anti-PLA2R-IgG concentration in 45 healthy volunteers, 31 IgA nephropathy, 9 lupus nephropathy, and 52 idiopathic membranous nephropathy patients was 0.53 ± 0.18 mg/L, 0.70 ± 0.41 mg/L, 1.08 ± 0.65 mg/L, and 9.00 ± 11.82 mg/L, respectively. The cut-off point for an abnormal anti-PLA2R-IgG concentration was defined as >0.89 mg/L. The positive rates in serum from patients with IgA nephropathy, lupus nephropathy, and idiopathic membranous nephropathy were 29.0%, 44.4%, and 88.5%, respectively. The availability of this quantitation method will facilitate the use of serum anti-PLA2R-IgG for diagnosing idiopathic membranous nephropathy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Purification, characterization and immunochemical detection

A phospholipase A2 (PLA2, EC 3.1.1.4) was purified from human cell-free ascitic fluid (a-PLA2) by ion-exchange chromatography and h.p.l.c. on a reverse-phase column to apparent homogeneity. The enzyme had an Mr of approx. 10000 as determined by SDS/PAGE. Polyclonal antibodies raised in a rabbit were specific to a-PLA2, as judged by immunoblotting. A time-resolved fluoroimmunoassay (TR-FIA) for ...

متن کامل

Time-resolved fluoroimmunoassay of human pancreatic phospholipase A2.

We describe an immunofluorometric assay for human pancreatic phospholipase A2 based on time-resolved fluorescence. The labeled antibody technique in combination with the time-resolved 1-s fluorometric detection of the europium label, which essentially eliminates all background fluorescence, resulted in a high sensitivity (20 ng/L) and a wide (5000-fold) linear range. Nonspecific binding was min...

متن کامل

Immunoreactive phospholipase A2 in serum in acute pancreatitis and pancreatic cancer.

Immunoreactive phospholipase A2 (EC 3.1.1.4) was measured by a new sensitive time-resolved fluoroimmunoassay in the serum of 58 healthy subjects and 103 patients with acute pancreatitis. Patients with acute pancreatitis were grouped according to the etiology and clinical severity of the disease. The mean phospholipase A2 concentration in the reference (healthy) group was 5.5 (SD 1.9) micrograms...

متن کامل

Immunochemical detection of group I and group II phospholipases A2 in human serum.

Time-resolved fluoroimmunoassay was developed for the detection of synovial-type phospholipase A2 (s-PLA2) in human serum. This solid-phase, sandwich assay uses a polyclonal rabbit antibody raised against synovial-type group II PLA2 produced in Escherichia coli. No cross-reactions were detected between s-PLA2 and PLA2 from human or porcine pancreas, human ascitic fluid, or bee or cobra venom. I...

متن کامل

Characterization of two phospholipases A2 in serum of patients with sepsis and acute pancreatitis.

Pancreatic phospholipase A2 and non-pancreatic ascitic phospholipases A2 were studied in sera of healthy individuals and of patients suffering from sepsis or acute pancreatitis. In gel filtration experiments, immunoreactive ascitic phospholipase A2, as determined in serum by a time-resolved fluoroimmunoassay, eluted either unassociated with an apparent M(r) of 10,000-14,000 or associated with p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017