A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results
نویسندگان
چکیده
BACKGROUND Hip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly relies on the optimal size and position of the femoral component. This can be defined before surgery with pre-operative templating. Reproducing the optimal, templated femoral implant position during surgery relies on guide wire positioning devices in combination with visual inspection and experience of the surgeon. Another method of transferring the templated position into surgery is by navigation or Computer Assisted Surgery (CAS). Though CAS is documented to increase accurate placement particularly in case of normal hip anatomy, it requires bulky equipment that is not readily available in each centre. METHODS A custom made neck jig device is presented as well as the results of a pilot study. The device is produced based on data pre-operatively acquired with CT-scan. The position of the guide wire is chosen as the anatomical axis of the femoral neck. Adjustments to the design of the jig are made based on the orthopedic surgeon's recommendations for the drill direction. The SRA jig is designed as a slightly more-than-hemispherical cage to fit the anterior part of the femoral head. The cage is connected to an anterior neck support. Four knifes are attached on the central arch of the cage. A drill guide cylinder is attached to the cage, thus allowing guide wire positioning as pre-operatively planned. Custom made devices were tested in 5 patients scheduled for total hip arthroplasty. The orthopedic surgeons reported the practical aspects of the use of the neck-jig device. The retrieved femoral heads were analyzed to assess the achieved drill place in mm deviation from the predefined location and orientation compared to the predefined orientation. RESULTS The orthopedic surgeons rated the passive stability, full contact with neck portion of the jig and knife contact with femoral head, positive. There were no guide failures. The jig unique position and the number of steps required to put the guide in place were rated 1, while the complexity to put the guide into place was rated 1-2. In all five cases the guide wire was accurately positioned. Maximum angular deviation was 2.9 degrees and maximum distance between insertion points was 2.1 mm. CONCLUSIONS Pilot testing of a custom made jig for use during SRA indicated that the device was (1) successfully applied and user friendly and (2) allowed for accurate guide wire placement according to the preoperative plan.
منابع مشابه
A modified custom-made triflanged acetabular reconstruction ring (MCTARR) for revision hip arthroplasty with severe acetabular defects.
The treatment of extensive acetabular bone loss and pelvic discontinuity in revision total hip arthroplasty remains challenging. We report our preliminary experience with the modified custom-made triflanged acetabular reconstruction ring (MCTARR) in the management of such situations. The MCTARR is a custom-made metal reinforcement ring with a trabecular surface to encourage bone ingrowth and a ...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملMating of a PROSTALAC spacer with an intramedullary nail for reconstruction of an infected interprosthetic femoral shaft fracture: a case report.
Reconstruction for concurrent infection of an ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is a challenge. We report a 2-stage reconstruction of a THA for chronic infection of both the THA and TKA with severe femoral bone loss secondary to interprosthetic fractures. The reconstruction involved using a custom-made, temporary, antibiotic-impregnated PROSTALAC spacer ...
متن کاملClinical Study for Measurement of Stem Antetorsion during Total Hip Arthroplasty. Ct Free Navigation Vs G-guide
Implant positioning is one of the critical factors influencing the postoperative outcome in total hip arthroplasty (THA) [1.2]. In our previous study, we evaluated the Combined anteversion (CA) value in patients who underwent THA using an image-free navigation for the cup with manual adjustment of the stem. Consequently, the AT value showed wide variability [3].Since March 2013, we have measure...
متن کاملFilling of segmental bone defects in revision knee arthroplasty using morsellized bone grafts contained within a metal mesh.
For revision knee surgery with uncontained tibial bone defects, the authors report the containment of compacted morsellized allograft using metal-wire mesh, followed by implantation of a cemented total knee prosthesis. This method is comparable to the "impaction grafting technique" described for revision hip surgery and could be an alternative to metal wedges, augmented components, custom-made ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2010