Noisy independent component analysis of autocorrelated components.
نویسندگان
چکیده
We present a method for the separation of superimposed, independent, autocorrelated components from noisy multichannel measurement. The presented method simultaneously reconstructs and separates the components, taking all channels into account, and thereby increases the effective signal-to-noise ratio considerably, allowing separations even in the high-noise regime. Characteristics of the measurement instruments can be included, allowing for application in complex measurement situations. Independent posterior samples can be provided, permitting error estimates on all desired quantities. Using the concept of information field theory, the algorithm is not restricted to any dimensionality of the underlying space or discretization scheme thereof.
منابع مشابه
Efficiency Measurement of Clinical Units Using Integrated Independent Component Analysis-DEA Model under Fuzzy Conditions
Background and Objectives: Evaluating the performance of clinical units is critical for effective management of health settings. Certain assessment of clinical variables for performance analysis is not always possible, calling for use of uncertainty theory. This study aimed to develop and evaluate an integrated independent component analysis-fuzzy-data envelopment analysis approach to accurate ...
متن کاملImproving the Performance of ICA Algorithm for fMRI Simulated Data Analysis Using Temporal and Spatial Filters in the Preprocessing Phase
Introduction: The accuracy of analyzing Functional MRI (fMRI) data is usually decreases in the presence of noise and artifact sources. A common solution in for analyzing fMRI data having high noise is to use suitable preprocessing methods with the aim of data denoising. Some effects of preprocessing methods on the parametric methods such as general linear model (GLM) have previously been evalua...
متن کاملRecognition of Multiple PQ Issues using Modified EMD and Neural Network Classifier
This paper presents a new framework based on modified EMD method for detection of single and multiple PQ issues. In modified EMD, DWT precedes traditional EMD process. This scheme makes EMD better by eliminating the mode mixing problem. This is a two step algorithm; in the first step, input PQ signal is decomposed in low and high frequency components using DWT. In the second stage, the low freq...
متن کاملA process monitoring method based on noisy independent component analysis
Independent component analysis (ICA) is an effective feature extraction tool for process monitoring. However, the conventional ICA-based process monitoring methods usually adopt noise-free ICA models and thus may perform unsatisfactorily under the adverse effects of the measurement noise. In this paper, a process monitoring method using a new noisy independent component analysis, referred to as...
متن کاملOverdetermined Blind Source Separation: Using More Sensors than Source Signals in a Noisy Mixture
This paper addresses the blind source separation problem for the case where more sensors than source signals are available. A noisy-sensor model is assumed. The proposed algorithm comprises two stages, where the first stage consists of a principal component analysis (PCA) and the second one of an independent component analysis (ICA). The purpose of the PCA stage is to increase the input SNR of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical review. E
دوره 96 4-1 شماره
صفحات -
تاریخ انتشار 2017