Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction.

نویسندگان

  • Nan-kuei Chen
  • Alice M Wyrwicz
چکیده

Odd-even echo inconsistencies result in Nyquist ghost artifacts in the reconstructed EPI images. The ghost artifacts reduce the image signal-to-noise ratio and make it difficult to correctly interpret the EPI data. In this article a new 2D phase mapping protocol and a postprocessing algorithm are presented for an effective Nyquist ghost artifacts removal. After an appropriate k-space data regrouping, a 2D map accurately encoding low- and high-order phase errors is derived from two phase-encoded reference scans, which were originally proposed by Hu and Le (Magn Reson Med 36:166-171;1996) for their 1D nonlinear correction method. The measured phase map can be used in the postprocessing algorithm developed to remove ghost artifacts in subsequent EPI experiments. Experimental results from phantom, animal, and human studies suggest that the new technique is more effective than previously reported methods and has a better tolerance to signal intensity differences between reference and actual EPI scans. The proposed method may potentially be applied to repeated EPI measurements without subject movements, such as functional MRI and diffusion coefficient mapping.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-Shot and Segmented EPI Ghost Artifacts Removal with Two-Dimensional Phase Correction

Introduction Asymmetry between odd and even echoes generates Nyquist ghost artifact in a single-shot EPI , and further enhances multiple ghost artifacts in a segmented EPI. These ghost artifacts not only severely degrade EPI image quality, but may lead to incorrect ADC values in EPI based diffusion measurements (1). Methods currently available for odd-even-echo asymmetry compensation include on...

متن کامل

Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

PURPOSE A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultaneously acquired slice-group. These navigator data may contain spatially nonlin...

متن کامل

Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.

Diffusion-weighted imaging (DWI) obtained with interleaved echo-planar imaging (EPI) pulse sequence has great potential of characterizing brain tissue properties at high spatial-resolution. However, interleaved EPI based DWI data may be corrupted by various types of aliasing artifacts. First, inconsistencies in k-space data obtained with opposite readout gradient polarities result in Nyquist ar...

متن کامل

Reference-free single-pass EPI Nyquist ghost correction using annihilating filter-based low rank Hankel matrix (ALOHA).

PURPOSE MR measurements from an echo-planar imaging (EPI) sequence produce Nyquist ghost artifacts that originate from inconsistencies between odd and even echoes. Several reconstruction algorithms have been proposed to reduce such artifacts, but most of these methods require either additional reference scans or multipass EPI acquisition. This article proposes a novel and accurate single-pass E...

متن کامل

Dual-Polarity GRAPPA for simultaneous reconstruction and ghost correction of EPI data

Purpose: We seek improved image quality from accelerated EPI data, particularly at ultra-high field. Certain artifacts in EPI reconstructions can be attributed to nonlinear phase differences between data acquired using frequency encoding gradients of alternating polarity. These errors appear near regions of local susceptibility gradients, and typically cannot be corrected with conventional Nyqu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 51 6  شماره 

صفحات  -

تاریخ انتشار 2004