BACKGROUND Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. CASE PRESENTATION During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. CONCLUSION The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound imaging. Appropriate training and supervised experience in ultrasound guided venous access coupled with quality ultrasound equipment would most likely have significantly diminished the likelihood of this complication. The potential for significant patient morbidity, and possible mortality, was prevented by implantation of an arterial stent-graft.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis

Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...

متن کامل

For Superior Visualization of the Thoracic Inlet Intraoperatively, and Minimizes Pain and Shoulder Dysfunction Postoperatively. Ecomment. Iatrogenic Subclavian Artery Injuries and Video-assisted Thoracic Sur- Gical Repair

[1] Ruesch S, Walder B, Tramèr MR. Complications of central venous catheters: internal jugular versus subclavian access—a systematic review. Critical Care Med 2002;30:454–60. [2] Scott WL. Complications associated with central venous catheters. A survey. Chest 1988;94:1221–24. [3] Huddy SP, McEwan A, Sabbat J, Parker DJ. Giant false aneurysm of the subclavian artery: an unusual complication of ...

متن کامل

Inadvertent Transarterial Lead Placement in the Left Ventricle and Aortic Cusp: Percutaneous Lead Removal with Carotid Embolic Protection and Stent Graft Placement

BACKGROUND/PURPOSE Transarterial lead implantation in the left ventricle or aorta is a rare complication. Percutaneous lead removal is associated with significant thromboembolic and bleeding risk. We present two cases of lead removal from the left ventricle via the left subclavian artery with concurrent carotid embolic protection followed by stent graft placement in the subclavian artery. MET...

متن کامل

Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases

Open surgical rerouting and proximal ligation of one or more supra-aortic vessels prior to endovascular stent-graft placement has become an alternative to major open thoracic surgery in the treatment of complex thoracic aortic disease. Complications owing to failed surgical ligation of the left subclavian artery are rare. In this report, 3 cases of failed ligation are presented. Diagnosis was m...

متن کامل

The real effectiveness of ultrasound guidance in subclavian venous access.

AIM The technique of ultrasound-guided subclavian cannulation was evaluated in our experience assessing the real effectiveness of such procedure. METHODS We have evaluated 297 subclavian cannulation, performed for the placement of central venous catheter both with landmark method (176 patients) and ultrasound guided technique (121 patients) to assess the real effectiveness of the ultrasound-g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BMC Medical Imaging

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006