Auditory cortical images of cochlear-implant stimuli: coding of stimulus channel and current level.

نویسندگان

  • John C Middlebrooks
  • Julie Arenberg Bierer
چکیده

This study quantified the accuracy with which populations of neurons in the auditory cortex can represent aspects of electrical cochlear stimuli presented through a cochlear implant. We tested the accuracy of coding of the place of stimulation (i.e., identification of the active stimulation channel) and of the stimulus current level. Physiological data came from the companion study, which recorded spike activity of neurons simultaneously from 16 sites along the tonotopic axis of the guinea pig's auditory cortex. In that study, cochlear electrical stimuli were presented to acutely deafened animals through a 6-electrode animal version of the 22-electrode Nucleus banded electrode array (Cochlear). Cochlear electrode configurations consisted of monopolar (MP), bipolar (BP + N) with N inactive electrodes between the active and return electrodes (0 < or = N < or = 3), tripolar (TP) with one active electrode and two flanking return electrodes, and common ground (CG) with one active electrode and as many as five return electrodes. In the present analysis, an artificial neural network was trained to recognize spatiotemporal patterns of cortical activity in response to single presentations of particular stimuli and, thereby, to identify those stimuli. The accuracy of pair-wise discrimination of stimulation channels or of current levels was represented by the discrimination index, d', where d' = 1 was taken as threshold. In many cases, the threshold for discrimination of place of cochlear stimulation was < 0.75 mm, and the threshold for discrimination of current levels was < 1 dB. Cochlear electrode configurations varied in the accuracy with which they signaled to the auditory cortex the place of cochlear stimulation. The BP + N and TP configurations provided considerably greater sensitivity to place of stimulation than did the MP configuration. The TP configuration maintained accurate signaling of place of stimulation up to the highest current levels, whereas sensitivity was degraded at high current levels in BP + N configurations. Electrode configurations also varied in the dynamic range over which they signaled stimulus current level. Dynamic ranges were widest for the BP + 0 configuration and narrowest for the TP configuration. That is, the configuration that showed the most accurate signaling of cochlear place of stimulation (TP) showed the most restricted dynamic range for signaling of current level. These results suggest that the choice of the optimal electrode configuration for use by human cochlear-prosthesis users would depend on the particular demands of the speech-processing strategy that is to be employed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Auditory cortical images of cochlear-implant stimuli: dependence on electrode configuration.

This study examines patterns of auditory cortical activity elicited by single-pulse cochlear implant stimuli that vary in electrode configuration, cochlear place of stimulation, and stimulus level. Recordings were made from the primary auditory cortex (area A1) of ketamine-anesthetized guinea pigs. The spatiotemporal pattern of neural spike activity was measured simultaneously across 16 cortica...

متن کامل

Influence of speech-coding strategy on cortical activity in cochlear implant users: a positron emission tomographic study.

The effects of a speech-coding strategy of cochlear implant (CI) on cortical activity were evaluated using positron emission tomography. The CIs used in the present study were those of a 22-channel system using the Multipeak speech-coding strategy (MPEAK) and the spectral peak strategy (SPEAK). On comparing the 2 groups, it was found that the speech-tracking performance was significantly higher...

متن کامل

Relationship between Electrically Evoked Compound Action Potential Thresholds and Auditory, Language, and Speech Progress after Cochlear Implant Surgery

Introduction: Electrically evoked compound action potential (ECAP) is an objective auditory response that can be used in the programing of cochlear implants. The aims of this study were to monitor ECAP thresholds and auditory, language and speech progress for 6 months after cochlear implant surgery and to evaluate any relationship between them.   Materials and Methods: Ten children with a m...

متن کامل

Can the acoustic change complex be recorded in an individual with a cochlear implant? Separating neural responses from cochlear implant artifact.

The purpose of this case study was to determine whether the P1-N1-P2 acoustic change complex (ACC) could be recorded in an individual with a cochlear implant. In a cochlear implant recipient, stimulus-related artifact from the implant can overlap the evoked potential of interest, making it difficult to determine whether the recorded response is neural or a simple reflection of the artifact. Thi...

متن کامل

Neurophysiology of cochlear implant users I: effects of stimulus current level and electrode site on the electrical ABR, MLR, and N1-P2 response.

OBJECTIVE As the need for objective measures with cochlear implant users increases, it is critical to understand how electrical potentials behave when stimulus parameters are systematically varied. The purpose of this study was to record and evaluate the effects of implanted electrode site and stimulus current level on latency, amplitude, and threshold measures of electrically evoked auditory p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 87 1  شماره 

صفحات  -

تاریخ انتشار 2002