Standard treatment for operable patients with single peripheral lung metastases is metastasectomy. We report mature CyberKnife outcomes for high-risk surgical patients with biopsy proven single peripheral lung metastases. Twenty-four patients (median age 73 years) with a mean maximum tumor diameter of 2.5 cm (range, 0.8-4.5 cm) were treated over a 6-year period extending from September 2004 to September 2010 and followed for a minimum of 1 year or until death. A mean dose of 52 Gy (range, 45-60 Gy) was delivered to the prescription isodose line in three fractions over a 3-11 day period (mean, 7 days). At a median follow-up of 20 months, the 2-year Kaplan-Meier local control and overall survival rates were 87 and 50%, respectively. CyberKnife with fiducial tracking is an effective treatment for high-risk surgical patients with single small peripheral lung metastases. Trials comparing CyberKnife with metastasectomy for operable patients are necessary to confirm equivalence.
منابع مشابه
Influence of different image-guided tracking methods upon the local efficacy of CyberKnife treatment in lung tumors
BACKGROUND The aim of this study was to explore the influence of image-guided tumor localization modality (Synchrony tracking vs. Xsight spine-based localization) on the local efficacy of CyberKnife treatment in lung cancer and lung metastases. METHODS Retrospective analysis of 64 patients with pulmonary metastases and primary tumor cases (72 targets) treated with stereotactic body radiothera...
متن کاملCyberKnife with Tumor Tracking: An Effective Treatment for High-Risk Surgical Patients with Stage I Non-Small Cell Lung Cancer
Published data suggests that wedge resection for stage I non-small cell lung cancer (NSCLC) is associated with improved overall survival compared to stereotactic body radiation therapy. We report CyberKnife outcomes for high-risk surgical patients with biopsy-proven stage I NSCLC. PET/CT imaging was completed for staging. Three-to-five gold fiducial markers were implanted in or near tumors to s...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملA quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates
Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...
متن کاملRobotic Radiosurgery for Adrenal Gland Metastases
INTRODUCTION The purpose of this study was to investigate the safety and efficacy of CyberKnife (CK) robotic radiosurgery for treatment of adrenal metastases. METHODS We performed a retrospective analysis of 23 patients with adrenal metastases who had been treated with CK between October 2006 and December 2015. Fifteen patients received chemotherapy prior to radiosurgery, all patients underwe...