Datum Definition Problems in Accelerator Alignment *

نویسنده

  • Robert Ruland
چکیده

Any measurement task requires a fixed reference base (the datum’) from which measurements can be made and calculated. The linac was the datum to which all SLC components were aligned; although this reference existed as a physical object, the actual establishment of the datum and its transferral to datums that were more useful for the SLC installation challenged the technology and computational ability of the survey group. Once established, the maintenance of datums is not to be taken for granted, as demonstrated by the 1989 earthquake which destroyed all SLAC’s survey datums.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RPS Alignment of Automotive Body Parts in Virtual Assembly and Deviation Analyses

Quality of products depends on various factors. The most important factors are inspection and measurement. The products have to be controlled in all phases of manufacturing. The production of automotive parts, medical devices, sport equipments or any other body parts has to be controlled in all phases of production. The most important usage is in sheet metal work-piece inspection. One of the la...

متن کامل

Algorithms for sensor chip alignment to blind datums

The sensor element of an imaging system should be mounted into its housing in such a way that the scene can be prop­ erly focused onto the sensor element’s focal plane over the active area. Operational imaging requirements are forcing increasingly smaller tolerances on sensor alignment, and manufacturing systems must improve alignment capability to keep pace. Imaging system designs include refe...

متن کامل

High Precision Survey and Alignment of Large Linear Accelerators

Future linear accelerators require new survey techniques to achieve the necessary alignment precision. For TESLA, the demanded accuracy for the alignment of the components is 0.5mm horizontal and 0.2mm vertical, both on each 600m section. Other proposed linear colliders require similar accuracies. These demands can not be fulfilled with common, open-air geodetic methods, mainly because of refra...

متن کامل

Alignment of the Stanford Linear Collider Arcs - Concepts and Results

A&TRACT The alignment of the Arcs for the Stanford Linear Collider at SLAC has posed problems in accelerator survey and alignment not encountered before. These problems come less from the tight tolerances of 0.1 mm, although reaching such a tight statistically defined accuracy in a controlled manner is difficult enough, but from the absence of a common reference plane fbr the Arcs. Traditional ...

متن کامل

On the Definition and Realization of a Global Vertical Datum

AGlobal Vertical Datum (GVD) is naturally defined by the geoid, and there is a well-established consensus to adopt Gauss-Bessel-Listing's definition of the geoid (i.e. as being the level surface of the Earth's gravity field that best fits the undisturbed sea level). Themain problem in defining the geoid is therefore to fix its constant geopotential (W0). Nevertheless, this definition can be int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1990