2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series

نویسندگان

  • Florian Gras
  • Ivan Marintschev
  • Arne Wilharm
  • Kajetan Klos
  • Thomas Mückley
  • Gunther O Hofmann
چکیده

BACKGROUND Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system. METHODS Between August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 +/- 1.2 month. RESULTS 56 iliosacral- and 29 ramus pubic-screws were inserted (mean operation time per screw 62 +/- 4 minutes, mean fluoroscopy time per screw 123 +/- 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure. CONCLUSION 2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique

Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...

متن کامل

Functional Outcome With Percutaneous Ilio-sacral Screw Fixation For Posterior Pelvic Ring Injuries In Patients Involved In Heavy Manual Laboring

INTRODUCTION Unstable posterior pelvic ring injuries are best treated with operative methods due to better post-op functional score. Our patient cohort was involved in heavy manual laboring frequently required ground level work in their activities of daily living. There are very few outcome studies dealing exclusively with such patients. MATERIALS & METHODS Forty one patients who were treated...

متن کامل

Anterior Pelvic Plating and Sacroiliac Joint Fixation in Unstable Pelvic Ring Injuries

PURPOSE To analyze the effectiveness of anterior pelvic plating and subsequent percutaneous sacroiliac joint screw fixation in patients with unstable pelvic ring injuries. MATERIALS AND METHODS Thirty-two patients were included with twenty-one males and eleven females. The mean age was 41 years (range, 19-76). The mean follow-up period was 51 months (range, 36-73). According to AO-OTA classif...

متن کامل

Superior Gluteal Artery Injury during Percutaneous Iliosacral Screw Fixation: A Case Report

Percutaneous iliosacral screw fixation is commonly practiced to treat unstable posterior pelvic ring injuries. The number of reported cases of iatrogenic complications is increasing. We present a case of superior gluteal artery injury during bilateral percutaneous iliosacral screw fixation in a patient with sacral fracture of spino-pelvic dissociation. This complication was managed by arterial ...

متن کامل

Outcome analysis of unstable posterior ring injury of the pelvis: comparison between percutaneous iliosacral screw fixation and conservative treatment.

BACKGROUND Unstable posterior ring injuries of the pelvis are a challenge to pelvic surgeons, and their treatment has been controversial. The functional outcomes of such injuries following either percutaneous iliosacral screw fixation or conservative treatment remain to be elucidated. METHODS We conducted a retrospective analysis of 32 consecutive patients with unstable pelvic ring injuries w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010