Nanoindentation of Polyethylene Tibial Components
نویسندگان
چکیده
Delamination is a common failure mechanism in ultra-high molecular weight polyethylene (UHMWPE) tibial inserts [Wright and Rimmnac, 1988]. Changes in polyethylene mechanical properties, such as subsurface embrittlement due to oxidation, may promote crack propagation. The assessment of through-thickness properties may, therefore, provide insight into delamination mechanisms. Using the small punch test [Kurtz et al., 1997], researchers have studied changes in subsurface mechanical properties in aged and unaged tibial components [Edidin et al., 1999; Ely et al., 2000]. In this present study, we used nanoindentation to measure stiffness and hardness profiles in cross sections of unused polyethylene tibial components. Nanoindentation has previously been used to characterize surface properties of UHMWPE [Schmidt et al., 2000].
منابع مشابه
Metal-backed and all-polyethylene tibial components in total knee replacement.
One hundred seventy-five patients with 243 consecutive primary Press Fit Condylar cruciate-substituting total knee replacements were evaluated at a mean of 5.5 years. One hundred thirteen knees had modular metal-backed tibial components and 130 had all-polyethylene tibial components. The mean knee score and functional score for the patients with unrevised components was not significantly differ...
متن کاملAll-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register.
BACKGROUND Currently, the use of metal-backed tibial components is more common than the use of all-polyethylene components in total knee arthroplasty. However, the available literature indicates that all-polyethylene tibial components are not inferior to the metal-backed design. We hypothesized that there would be no difference in the ten-year survival rate between all-polyethylene and metal-ba...
متن کاملClinical Outcomes of Tibial Components with Modular Stems Used in Primary TKA
Due to the known potential for fretting and corrosion at modular junctions in orthopaedic implants, this retrospective study evaluated radiographic and clinical outcomes of 85 primary TKA patients implanted with modular stemmed tibial components and followed up for an average of 82 months. There was low incidence of tibial radiolucent lines, excellent functional outcomes, and no complications a...
متن کاملThe all-polyethylene tibial component in primary total knee arthroplasty.
Outcomes of total knee arthroplasties performed with modern all-polyethylene tibial components have been found to be comparable with or better than those of arthroplasties done with metal-backed modular components in numerous mid-to-long-term follow-up studies, radiostereometric analyses, and the few prospective randomized trials available. Advantages of an all-polyethylene tibial component ove...
متن کاملMetal-backed versus all-polyethylene tibial components in primary total knee arthroplasty
BACKGROUND AND PURPOSE The choice of either all-polyethylene (AP) tibial components or metal-backed (MB) tibial components in total knee arthroplasty (TKA) remains controversial. We therefore performed a meta-analysis and systematic review of randomized controlled trials that have evaluated MB and AP tibial components in primary TKA. METHODS The search strategy included a computerized literat...
متن کامل