Fluorescent cardiac imaging: a novel intraoperative method for quantitative assessment of myocardial perfusion during graded coronary artery stenosis.

نویسندگان

  • Christian Detter
  • Sabine Wipper
  • Detlef Russ
  • Andre Iffland
  • Lars Burdorf
  • Eckart Thein
  • Karl Wegscheider
  • Hermann Reichenspurner
  • Bruno Reichart
چکیده

BACKGROUND The purpose of the present study was to examine whether the effect of coronary stenoses of variable severity on myocardial perfusion can be quantitatively assessed in vivo by analysis of fluorescent cardiac imaging (FCI) compared with the gold standard, the fluorescent microsphere method. FCI is a novel technology to visualize coronary vessels and myocardial perfusion intraoperatively using the indocyanine green dye with an infrared-sensitive imaging device. METHODS AND RESULTS Graded stenoses and total vessel occlusion of the left anterior descending coronary artery were created in 11 open-chest pigs. Stenoses were graded to reduce resting left anterior descending coronary artery flow by 25%, 50%, 75%, and 100% of baseline flow measured by transit-time flowmeter. FCI images were analyzed with a digital image processing system. The impairment of myocardial perfusion was quantified by background-subtracted peak fluorescence intensity and slope of fluorescence intensity obtained with FCI and compared with myocardial blood flow assessed by fluorescent microsphere. All stenoses resulted in an impairment of myocardial perfusion visualized by FCI. Occlusion of the left anterior descending coronary artery resulted in a total perfusion defect (no fluorescence intensity) of the corresponding anterior myocardial wall. During graded stenosis and total vessel occlusion, normalized background-subtracted peak fluorescence intensity and slope of fluorescence intensity decreased significantly (P<0.0001). Both background-subtracted peak fluorescence intensity (r=0.92, P<0.0001) and slope of fluorescence intensity (r=0.93, P<0.0001) analyzed by FCI demonstrated good linear correlation with fluorescent microsphere-derived myocardial blood flow. CONCLUSIONS The impairment of myocardial perfusion in response to increased coronary stenosis severity and total vessel occlusion can be quantitatively assessed by FCI and correlates well with results obtained by fluorescent microsphere.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Effect of Injected Dose of 99mTc- MIBI on the Quantitative Parameters of Myocardial Perfusion Imaging

Background: 99mTc-MIBI cardiac perfusion scanning is recognized as a clinically useful method in evaluating coronary artery disease. By the implementation of new imaging techniques and systems, it seems possible to obtain high-quality images with a lower dose of radiopharmaceuticals. The purpose of this study was to evaluate the effect of injection dose of 99mTc-MIBI on quantitative parameters ...

متن کامل

Quantitative assessment of myocardial perfusion during graded coronary artery stenoses by intravenous myocardial contrast echocardiography.

OBJECTIVES The purpose of this study was to examine whether coronary stenoses of variable severity could be quantitatively assessed by analysis of myocardial perfusion as determined by intravenous (IV) myocardial contrast echocardiography. BACKGROUND Recently, new contrast agents and imaging technology have been developed that may enable improved assessment of myocardial perfusion by IV contr...

متن کامل

Relationship between the location of the most severe myocardial perfusion defects, the most severe coronary artery stenosis and the site of subsequent myocardial infarction [Persian]

This study evaluated the relationship between the location of the most severe coronary artery stenosis and the subsequent acute myocardial infarction (AMI). Methods: Of 1590 patients who were admitted with a diagnosis of AMI, we identified 44 patients who had undergone previous myocardial perfusion SPECT. Thirty-one of these patients also had previous coronary angiography. The relationshi...

متن کامل

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

Filter selection for 99mTc-Sestamibi myocardial perfusion SPECT imaging [Persian]

Myocardial perfusion SPECT imaging with Tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. Though simple and straight forward the results produced by the technique is very much affected by the details being used. One of the main problems with the test, wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 116 9  شماره 

صفحات  -

تاریخ انتشار 2007