Asian-Specific total knee system: 5-14 year follow-up study

نویسندگان

  • Kunihiro Hosaka
  • Shu Saito
  • Takao Ishii
  • Sei Mori
  • Takanobu Sumino
  • Yasuaki Tokuhashi
چکیده

BACKGROUND Knee size and body size differ in Asians compared with Caucasians. Nevertheless, many total knee arthroplasty (TKA) prostheses used worldwide are made for Western Caucasian subjects. As a result, an Asian's knee might not fit these prostheses. We studied the Flexible Nichidai Knee (FNK) system, a new model of TKA for Asian patients. The purpose of this report is to investigate the outcomes of this prosthesis retrospectively. METHODS We investigated 1055 primary TKAs in 595 patients who underwent FNK for osteoarthritis (OA) in Japan and were followed for > 5 years. The knee score and function score were used for clinical evaluation. We examined the range of motion (ROM) preoperatively and at final follow-up and radiographic assessments. In addition, postoperative complications were investigated. A survivorship analysis was also conducted using two endpoints: revision for any reason and aseptic failure. RESULTS 890 knees in 502 patients were available for study (follow-up rate of 96.0%). The mean follow-up term was 8.3 years (range, 5.0-14.1 years). The knee and function score significantly improved from 41.3 to 90.3 and from 39.1 to 76.2 points, respectively (p < 0.001). The mean ROM in FNK posterior cruciate retaining (CR) type and FNK posterior-stabilized (PS) type ameliorated significantly from 107.8° and 95.6° to 110.7° and 110.4°, respectively (p < 0.01). Ten knees underwent revision surgery (infection in 3 cases, instability in 2, loosening in 2, and non-union of femoral supracondylar fracture, severe pain, and recurrent hemarthrosis in 1 each). The survivorship rate was 99.4% (95% CI, 99.0-99.8) at 5 years (n = 952 patients at risk) and 96.2% (95% CI, 91.9-100) at 12.5 years (n = 49 patients at risk). CONCLUSION The FNK prosthesis for Asians achieved excellent mid- to long-term survivorship and clinical results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mid-Term Results of Oxford Medial Unicompartmental Knee Arthroplasty in Young Asian Patients Less than 60 Years of Age: A Minimum 5-Year Follow-up

Purpose The purpose of this study was to evaluate the efficacy of unicompartmental knee arthroplasty (UKA) in young active Asian patients by analyzing clinical outcomes, complications and survival rates. Materials and Methods Eighty-two knees were evaluated with a minimum follow-up of 5 years after Oxford phase 3 UKA in patients less than 60 years of age at the time of surgery. Their mean age...

متن کامل

Survivorship analysis of the Kinematic Stabilizer total knee replacement: a 10- to 14-year follow-up.

The Kinematic Stabilizer is a posterior-cruciate-substituting design of total knee replacement. We have reviewed 109 primary total knee replacements in 95 patients at a mean follow-up time of 12.7 years (10 to 14). We used survival analysis with failure defined as revision of the implant. This gave a cumulative survival rate of 95% (95% CI +/- 5%) at ten years and (87% +/- 10%) at 13 years. The...

متن کامل

High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results

PURPOSE This study is to report clinical and radiological results of high-flexion total knee arthroplasty (TKA) using NexGen LPS-flex system at a minimum 5-year follow-up, and to analyze the implant survivorship based on the results. MATERIALS AND METHODS A total of 80 patients (118 knees) who underwent patellar preserving TKA using NexGen LPS-flex implant between February 2007 and February 2...

متن کامل

Epidemiology of post-operative venous thromboembolism in Asian patients. Results of the SMART venography study.

BACKGROUND AND OBJECTIVES The rate of post-operative asymptomatic deep-vein thrombosis in Asian patients remains uncertain. The aim of this study was to estimate the rate of venous thromboembolism, including asymptomatic deep-vein thrombosis, undergoing hip or knee surgery and not receiving pharmacological thromboprophylaxis. DESIGN AND METHODS This was a prospective observational study of a ...

متن کامل

Hybrid total knee arthroplasty: 10- to 16-year follow-up.

A cementless femoral component may allow for a smaller surgical incision when a minimally invasive approach is used during primary total knee arthroplasty. Fixation by cement is the gold standard for total knee arthroplasty. The results of cementless total knee arthroplasty are mixed. Cementless femoral components have done well. Although some tibial components have performed well at long-term ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011