Hemodynamic sensing using subcutaneous photoplethysmography.

نویسندگان

  • Robert G Turcott
  • Todd J Pavek
چکیده

Pacemakers and implantable defibrillators presently operate without access to hemodynamic information. If available, such data would allow tailoring of delivered therapy according to perfusion status, optimization of device function, and enhancement of disease monitoring and management. A candidate method for hemodynamic sensing in these devices is photoplethysmography (PPG), which uses light to noninvasively detect changes in blood volume. The present study tested the hypotheses that PPG can function in a subcutaneous location, that the acute changes in blood volume it detects are directly proportional to changes in arterial pressure, and that optimum pacing intervals identified by it are concordant with those determined by arterial pressure. Aortic pressure and PPG were simultaneously recorded in 10 dogs under general anesthesia during changes in atrioventricular (AV) delay and bursts of rapid pacing to simulate tachyarrhythmias. Direct proportionality between transient changes in pressure and PPG waveforms was tested using regression analysis. Scatter plots had a linear appearance, with correlation coefficients of 0.95 (SD 0.03) and 0.72 (SD 0.24) for rapid-pacing and AV delay protocols, respectively. The data were well described by a directly proportional relationship. Optimum AV delays estimated from the induced changes in aortic pressure and PPG waveforms were concordant. This preliminary canine study demonstrates that PPG can function subcutaneously and that it may serve as a surrogate for acute changes in arterial pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative Methodology Hemodynamic sensing using subcutaneous photoplethysmography

Turcott RG, Pavek TJ. Hemodynamic sensing using subcutaneous photoplethysmography. Am J Physiol Heart Circ Physiol 295: H2560 –H2572, 2008. First published October 10, 2008; doi:10.1152/ajpheart.00574.2008.—Pacemakers and implantable defibrillators presently operate without access to hemodynamic information. If available, such data would allow tailoring of delivered therapy according to perfusi...

متن کامل

Perioperative hemodynamic optimization using the photoplethysmography in colorectal surgery (the PANEX3 trial): study protocol for a randomized controlled trial

BACKGROUND Photoplethysmography with a digital sensor (ClearSight, Edwards Lifesciences, Irvine, CA, USA) connected to a dedicated monitor (EV 1000, Edwards Lifesciences) was recently proposed for use in performing hemodynamic optimization during surgery. The objective of this study is to evaluate the effect of photoplethysmography on the incidence of postoperative complications compared with t...

متن کامل

Prominence Of Low Frequency Rhythm In The Human Body During Deep Breathing As Monitored By Photoplethysmography

Optical sensors that use photons as sensing elements are increasingly becoming important and relevant in the field of non-invasive diagnostics. The reason is that they have a simple construction, easy to use and relatively inexpensive in comparison with tools such as EEG, MRI and FMRI that can be use for research purposes without much investment. Among the various optical sensors available, the...

متن کامل

Evaluation of Fluid Responsiveness: Is Photoplethysmography a Noninvasive Alternative?

Background. Goal-directed fluid therapy reduces morbidity and mortality in various clinical settings. Respiratory variations in photoplethysmography are proposed as a noninvasive alternative to predict fluid responsiveness during mechanical ventilation. This paper aims to critically evaluate current data on the ability of photoplethysmography to predict fluid responsiveness. Method. Primary sea...

متن کامل

Optical Sensor Based Instrument for Correlative Analysis of Human ECG and Breathing Signal

Optical sensors that use photons as sensing elements are increasingly becoming important and relevant in the field of non-invasive diagnostics. The reason is that they have a simple construction, easy to use and relatively inexpensive in comparison with tools such as EEG, MRI and FMRI that can be use for research purposes without much investment. Among the various optical sensors available, the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 295 6  شماره 

صفحات  -

تاریخ انتشار 2008