A novel electrochemical microsensor for the determination of NO and its application to the study of the NO donor S-nitrosoglutathione.
نویسندگان
چکیده
A novel electrochemical microsensor for the determination of NO based on an electropolymerized film of tetraaminophthalocyaninecopper [Cu(TAPc)] was prepared. Its response to NO and its application to the study of an NO donor (S-nitrosoglutathione; GSNO) are also described. The microsensor exhibited an electrocatalytic effect on NO oxidation and showed a low detection limit, high sensitivity and selectivity for NO determination. The oxidation current (measured by differential pulse amperometry) was linear for NO concentrations ranging from 6.2 x 10(-9) to 3.0 x 10(-5) mol L-1 with a calculated detection limit of 4.0 x 10(-9) mol L-1 (S/N = 3) and a linear coefficient of 0.9984. Some endogenous electroactive substances in biological tissues, such as dopamine, 5-hydroxytryptamine and nitrite, at concentrations higher than those in biological systems did not interfere with NO determination. The sensor shows promise for the possible in vivo determination of NO. Using the microsensor, the NO release from the NO donor (GSNO) was successfully monitored. This work sets a foundation for the study of the pharmacology and the biological effects in vivo of S-nitrosothiols.
منابع مشابه
Fabrication of TiO2 Hollow Spheres and its Application in Modification of Carbon Paste Electrode For Simultaneous Determination of Dopamine and Piroxicam in the Presence of Ascorbic acid
In this work we report preparation TiO2 hollow spheres and its application as an electrochemical sensor. Therefore the novel carbon paste electrode modified with TiO2 hollow spheres (TOHS), multi-walled carbon nanotubes (MWCNTs) and poly-glutamic acid (PGA) film (PGA/TOHS/MWCNTs/CPE) was used for simultaneous determination of dopamine (DA) and piroxicam (PRX) in the presence of ascorbic acid (A...
متن کاملElectrochemical production of Graphene Oxide and its application as a novel Hydrogen Peroxide sensor
Herein, graphene oxide is produced by electrochemical oxidation method from graphite rod to examine its hydrogen peroxide sensing ability. The electrochemically produced graphene oxide is characterized by SEM and XRD. A few layers of Graphene Oxide(GO) sheets and corrugations in graphene sheets appeared intensely crumpled and folded into a typical wrinkled structure after electrochemical oxidat...
متن کاملElectrochemical Determination of Mesalazine by Modified Graphite Paste Electrode with Poly (Benzoquinone) Chromium(III) Complex
In this work, for the first time poly (benzoquinone) chromium (III) complex (PBQC) was synthesized with a one pot, one step, simple and fast method. This novel polymer was used for modification of graphite paste electrode for electrochemical determination of Mesalazine. Moreover, this novel modifier was characterized by Fourier transform infrared spectroscopy, Field emission scanning electron m...
متن کاملAMPEROMETRIC MICROBIOSENSOR FOR THE DETERMINATION OF CHOLINE
The construction and performance of an amperometric microbiosensor for the determination of choline chloride by immobilizing choline oxidase on a cellulose acetate membrane are described. The procedure of choline determination involved the electrochemical detection of enzymatically generated hydrogen peroxide. This microsensor has a linear response between 0.038-0.1 mM choline chloride. The...
متن کاملDevelopment of electrochemical aptasensor based on gold nanorod and its application for detection of aflatoxin B1 in rice and blood serum sample
Aflatoxins are a group of fungal mycotoxins produced mainly by molds, e.g. Aspergillus flavus and Aspergillus parasiticus. Among Aflatoxins, Aflatoxin B1 (AFB1) is the most toxic. Therefore, there is a prompt need for determination of AFB1 in food products. This paper reports an electrochemical aptasensor for accurate determination of AFB1, which was constructed by the using gold nanorod sensin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 125 1 شماره
صفحات -
تاریخ انتشار 2000