Comparison of three nucleic acid amplification tests for detection of Chlamydia trachomatis in urine specimens.
نویسندگان
چکیده
Traditionally, culture and immunoassays have been performed for the detection of sexually transmitted diseases, including Chlamydia trachomatis. However, these assays may often require invasive specimen collection methods, such as female cervical and male urethral swabs. Recently, nucleic acid amplification tests (NAATs) have been approved for testing for the presence of C. trachomatis in urine samples. Our objective was to compare the sensitivities and specificities of C. trachomatis detection in urine samples with three NAATs: the Abbott LCx (LCx), BD ProbeTec ET (ProbeTec), and Gen-Probe APTIMA Combo 2 (AC2). Urine specimens (n = 506) were collected from both symptomatic and asymptomatic males and females from various high school health clinics. Specimens were tested for C. trachomatis with the three NAATs, and a true-positive result was defined as any two positive NAATs. The C. trachomatis prevalence was 14.8% (75 of 506 samples). Of the 75 urine samples defined as true positives, LCx detected 72, ProbeTec 72, and AC2 detected 75. The sensitivities of LCx, ProbeTec, and AC2 for C. trachomatis detection were 96.0, 96.0, and 100%, and the specificities were 99.1, 100, and 98.8%, respectively. Four of five samples that were positive with AC2 and negative with LCx and ProbeTec were found to be positive with an alternative target TMA-based NAAT, APTIMA C. trachomatis, suggesting that they may have been true positives. Two of four uniquely positive LCx samples available for subsequent testing were both found to be positive by Roche PCR. We found that the LCx, ProbeTec, and AC2 NAATs are highly sensitive and specific methods for the detection of C. trachomatis in urine specimens and can be recommended for noninvasive screening of C. trachomatis in urine.
منابع مشابه
Volume effect on sensitivity of nucleic acid amplification tests for detection of Chlamydia trachomatis in urine specimens from females.
Nucleic acid amplification tests (NAATs) for the detection of Chlamydia trachomatis are routinely used on first-catch urine (FCU) specimens. We analyzed data from a head-to-head comparison of NAATs on female FCU specimens and found that the volume of urine collected could affect test performance.
متن کاملEvaluation of three automated nucleic acid amplification systems for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in first-void urine specimens.
A total of 500 first-void urine specimens were tested for the presence of Chlamydia trachomatis and Neisseria gonorrhoeae nucleic acids using ProbeTec ET reagents on a Viper platform (BD Diagnostics, Mississauga, Ontario, Canada), Aptima Combo 2 reagents on a Tigris platform (Gen-Probe, Inc., San Diego, CA), and Abbott RealTime CT/NG reagents on an m2000 platform (Abbott Molecular Diagnostics, ...
متن کاملUrine specimens from pregnant and nonpregnant women inhibitory to amplification of Chlamydia trachomatis nucleic acid by PCR, ligase chain reaction, and transcription-mediated amplification: identification of urinary substances associated with inhibition and removal of inhibitory activity.
The presence of endogenous amplification inhibitors in urine may produce false-negative results for the detection of Chlamydia trachomatis nucleic acids by tests such as PCR, ligase chain reaction (LCR), and transcription-mediated amplification (TMA). Consecutive urine specimens from 101 pregnant women and 287 nonpregnant women submitted for urinalysis were processed for C. trachomatis detectio...
متن کاملDetection of Chlamydia trachomatis in urine samples by nucleic acid tests: comparison with culture and enzyme immunoassay of genital swab specimens.
Two commercially available nucleic acid-based tests, ligase chain reaction (LCR; Abbott Laboratories) and PCR (Roche Diagnostics), for the detection of Chlamydia trachomatis in male and female urine samples were compared with culture and enzyme immunoassay (EIA) (Microtrak; Syva) for C. trachomatis detection in genital samples. The samples were collected from 1,005 patients who attended a sexua...
متن کاملExternal quality assessment program for Chlamydia trachomatis diagnostic testing by nucleic acid amplification assays.
We report the results from 57 Australian diagnostic laboratories testing two external quality assessment panels using either the Roche Amplicor Chlamydia trachomatis test (R-PCR) or the Abbott LCx Chlamydia trachomatis assay (A-ligase chain reaction [LCR]). Panel samples were either normal urine spiked with Chlamydia trachomatis antigen or clinical urine specimens. There was no significant diff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 42 7 شماره
صفحات -
تاریخ انتشار 2004