Study of MgB2 HEB mixers at THz frequencies

نویسنده

  • Evgenii Novoselov
چکیده

The terahertz (THz) range is very attractive for astronomical observations. Spectroscopy and photometry of remote space objects in the THz range allows for a study of their chemical composition, because this range covers rotational lines from simple molecules and electron transition lines from atoms and ions. Heterodyne receivers, due to their high spectral resolution, in the THz range allows for a studying of dynamical behaviour of space objects manifested in doppler-shifted emission lines. Niobium nitride (NbN) hot-electron bolometer (HEB) mixers currently used at frequencies >1THz provide a typical gain bandwidth (GBW) of 3– 4GHz which limits the number of astronomical applications. Moreover, the low (8–11K) critical temperature (Tc) of NbN ultra-thin films necessitates a use of liquid helium (LHe) for the device cooling, which reduce a lifetime of spaceborn missions. MgB2 HEB mixers, introduced recently, can solve both of these problems. The high (39K) Tc and the short (3 ps) electron-phonon interaction time of MgB2 could provide a bandwidth up to 10GHz and operation at temperatures >20K, where compact cryocoolers are available. However, the sensitivity of HEB mixers made from MgB2 thin films with such a high Tc operating at these temperatures is still in question. This thesis presents the noise performance study of novel submicron size MgB2 HEB mixers. Noise temperatures and conversion gains at 1.6THz local oscillator (LO) of devices with different Tc were investigated with respect to the bath temperature. The minimum Double sideband (DSB) noise temperature for a “low” Tc HEB was 700K with a 3.2GHz noise bandwidth (NBW) and 1150K with a 3.5GHz NBW for 2.7K and 4.2K bath temperatures, respectively. The operation at a bath temperature of 12K was demonstrated showing a 2150K noise temperature and a 5GHz NBW. At a bath temperature of 4.2K the noise temperature reduced to 1700K keeping a NBW of 5GHz. The same 3.5GHz GBW was measured for both bath temperatures. The voltage responsivity of such a device was estimated to be 1–2 kV/W at 1.6THz. The results of preliminary noise measurements at a 2.6THz LO as well as modeling of HEB conversion gain using the standard model are presented. Based on this research operation of MgB2 HEB mixers with Tc >30K at bath temperatures >20K is suggested with no or acceptable sensitivity reduction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MgB2 hot-electron bolometer mixers for THz heterodyne instruments

In this work we present experimental investigation of the MgB2 hot-electron bolometer (HEB) for low noise mixing at terahertz frequencies. A dedicated MgB2 thin film deposition system was designed and constructed based on Hybrid Physical-Chemical Deposition. Films as thin as 15nm have a superconducting transition at 35K, with a critical current density >107 A/cm2 (at 4.2K) in bridges as narrow ...

متن کامل

Characterisation and Modeling of MgB2 HEBs IF impedance

The Terahertz region of the electromagnetic spectrum which offers many molecular and atomic emission is of particular interest for astrophysics [1]. In order to explore the THz frequency band low noise heterodyne receiver are required. Hot electron bolometers (HEB) are the most sensitive THz mixers for frequencies above 1 THz offering a gain bandwidth (GBW) as wide as 4 GHz [2]. HEBs made from ...

متن کامل

Wideband THz HEB mixers using HPCVD MgB2 thin films

We present results of experimental study of the gain bandwidth (GBW) of MgB2 hot electron-bolometer (HEB) mixers at 0.1THz and 0.4THz. Antenna integrated 0.25-1.5um2 area devices were made from thin MgB2 films deposited with a custom made HPCVD system. Film as thin as 15-45nm had a Tc from 35K to 40K. The GBW was found to be independent on the bias conditions, the bath temperature, and the LO f...

متن کامل

MgB2 Hot-Electron Bolometer Mixers at Terahertz Frequencies

In this paper we compare the performance of MgB2 Hot-Electron Bolometer Mixers operating at Local Oscillator frequencies of 0.6 THz and 1.63 THz. The minimum noise temperatures that were obtained are 700 K and 1150 K for 0.6 THz and 1.63THz respectively. The receiver noise bandwidth is of the order of 2.2-3GHz for 10nm thick HEB devices with a Tc of 8.5K. Sub-micrometer size HEBs were also fabr...

متن کامل

Broadband MgB2 Hot-Electron Bolometer THz Mixers operating up to 20K

We discuss performance of submicron size hotelectron bolometer (HEB) mixers made from thin MgB2 superconducting films. With a superconducting transition temperature of 30K, such THz mixers can operate with high sensitivity at temperatures up to 20K. Due to very small dimensions local oscillator (LO) power requirements are rather low. In the intermediate frequency (IF) band of 1-3GHz the double...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015